English
Language : 

IC-ML Datasheet, PDF (6/17 Pages) IC-Haus GmbH – HALL Position Sensor / Encoder
iC-ML
HALL Position Sensor / Encoder
OPERATING CONDITIONS: Logic
Operating conditions: VDD = 5 V ±10 %, Tj = -40...125 °C, unless otherwise noted
Input level low = 0...0.45 V, high = 2.4 V...VDD, timing according Fig. 4
Item Symbol Parameter
No.
Conditions
Logic
I001 ts(NEN) Setup time NEN
CLK : low → high, see Fig. 15
I002 tp(NEN) Delay time NENO
CLK : high → low, see Fig. 15
I003 tp(SIG1) Delay time SIG1
CL() = 50 pF, see Fig. 15
I004 tp(SIG2) Delay time SIG2
CL() = 50 pF, see Fig. 15
I005 tp(CFGx) Setup time at CFGx, x = 1..3
see Fig. 9
V
2.4V
2.0V
Input/Output
0.8V
0.45V
t
1
0
Figure 4: Reference levels for delays
Rev A3, Page 6/17
Min.
30
Unit
Max.
ns
30
ns
60
µs
2
µs
4
µs