iC-LNG 16-BIT OPTO ENCODER preliminary
WITH SPI AND SERIAL / PARALLEL OUTPUTS
Rev B1, Page 21/30
has not finished, etc., the internal address counter is incremented no further and the FAIL error bit is set in
the status byte (Table 14).
CS
SCLK
MOSI
MISO
OP ADR DATA1 DATA2 ...
OP
ADR DATA1 DATA2 ...
8 cycles
Figure 13: Write to REGISTER (cont.)