English
Language : 

IC-LO_16 Datasheet, PDF (17/25 Pages) IC-Haus GmbH – TRIANGULATION SENSOR
iC-LO
TRIANGULATION SENSOR
TAF
Addr. 0x0A; bit 1:0
RW
Code
Description
0x0
0 ms
0x1
5 ms
0x2
20 ms
0x3
50 ms
Table 25: Fall Delay
preliminary
Rev B3, Page 17/25
SYSTEM CLOCK
The frequency of the internal oscillator must be trimmed OSC
Addr. 0x0B; bit 3:0
RW
to ensure correct timing. For this purpose the system Code
Description
clock can be output at pin WARN using the command 0x0
-20%
OSC_OUT_ON (table 27).
0x1
-17.5%
...
0x8
0%
...
0xF
17.5%
Table 26: System Clock Setting