English
Language : 

HPMX-2005 Datasheet, PDF (7/12 Pages) Agilent(Hewlett-Packard) – Silicon Bipolar RFIC 100 MHz Vector Modulator
HPMX-2005 Modulation Accuracy (Sample Part)
VCC = 5 V, LO = -12 dBm, VIref = VQref = 2.5 V, √(VImod - 2.5)2 + (VQmod - 2.5)2 = 0.75 V, TA = 25°C
(unless otherwise noted).
0.6
0.5
0.4
0.4
0.2
0.3
0
0.2
-0.2
0.1
-0.4
-0.6
0
90
180
270
INPUT PHASE (DEGREES)
Figure 19. HPMX-2005 RMS Amplitude Error vs. Input Phase at 100 MHz.
0
360
-55 -35 -15 5 25 45 65 85
TEMPERATURE (°C)
Figure 20. HPMX-2005 RMS Amplitude
Error at 100 MHz vs. Temperature.
6
4
2
0
-2
-4
-6
0
90
180
270
INPUT PHASE (DEGREES)
Figure 21. HPMX-2005 Phase Error vs. Input Phase at 100 MHz.
5
4
3
2
1
0
360
-55 -35 -15 5 25 45 65 85
TEMPERATURE (°C)
Figure 22. HPMX-2005 RMS Phase
Error at 100 MHz vs. Temperature.
5
5
4
4
3
3
2
2
1
1
0
0
90
180
270
360
INPUT PHASE (DEGREES)
Figure 23. HPMX-2005 RMS Modulation Error vs. Input Phase at 100 MHz. This
value is calculated from the values of amplitude and phase error.
0
-55 -35 -15
5 25
45 65 85
TEMPERATURE (°C)
Figure 24. HPMX-2005 RMS
Modulation Error at 100 MHz vs.
Temperature.
7-60