English
Language : 

HCPL-3150 Datasheet, PDF (7/15 Pages) Agilent(Hewlett-Packard) – 0.5 Amp Output Current IGBT Gate Drive Optocoupler
Notes:
1. Derate linearly above 70°C free-air
temperature at a rate of 0.3 mA/°C.
2. Maximum pulse width = 10 µs,
maximum duty cycle = 0.2%. This
value is intended to allow for
component tolerances for designs
with IO peak minimum = 0.5 A. See
Applications section for additional
details on limiting IOH peak.
3. Derate linearly above 70°C free-air
temperature at a rate of 4.8 mW/°C.
4. Derate linearly above 70°C free-air
temperature at a rate of 5.4 mW/°C.
The maximum LED junction tempera-
ture should not exceed 125°C.
5. Maximum pulse width = 50 µs,
maximum duty cycle = 0.5%.
6. In this test VOH is measured with a dc
load current. When driving capacitive
loads VOH will approach VCC as IOH
approaches zero amps.
7. Maximum pulse width = 1 ms,
maximum duty cycle = 20%.
8. In accordance with UL1577, each
optocoupler is proof tested by
applying an insulation test voltage
≥ 3000 Vrms for 1 second (leakage
detection current limit, II-O ≤ 5 µA).
This test is performed before the
100% production test for partial
discharge (method b) shown in the
VDE 0884 Insulation Characteristics
Table, if applicable.
9. Device considered a two-terminal
device: pins 1, 2, 3, and 4 shorted
together and pins 5, 6, 7, and 8
shorted together.
10. The difference between tPHL and tPLH
between any two HCPL-3150 parts
under the same test condition.
11. Pins 1 and 4 need to be connected to
LED common.
12. Common mode transient immunity in
the high state is the maximum
tolerable |dVCM/dt| of the common
mode pulse, VCM, to assure that the
output will remain in the high state
(i.e., VO > 15.0 V).
13. Common mode transient immunity in
a low state is the maximum tolerable
|dVCM/dt| of the common mode
pulse, VCM, to assure that the output
will remain in a low state (i.e.,
VO < 1.0 V).
14. This load condition approximates the
gate load of a 1200 V/25 A IGBT.
15. Pulse Width Distortion (PWD) is
defined as |tPHL-tPLH| for any given
device.
0
IF = 7 to 16 mA
IOUT = -100 mA
VCC = 15 to 30 V
-1
VEE = 0 V
-2
-3
-4
-40 -20 0 20 40 60 80 100
TA – TEMPERATURE – °C
0.50
0.45
IF = 7 to 16 mA
VOUT = VCC - 4 V
VCC = 15 to 30 V
VEE = 0 V
0.40
0.35
0.30
0.25
-40 -20 0 20 40 60 80 100
TA – TEMPERATURE – °C
-1
100 °C
-2
25 °C
-40 °C
-3
-4
IF = 7 to 16 mA
-5 VCC = 15 to 30 V
VEE = 0 V
-6
0 0.2 0.4 0.6 0.8 1.0
IOH – OUTPUT HIGH CURRENT – A
Figure 1. VOH vs. Temperature.
Figure 2. IOH vs. Temperature.
Figure 3. VOH vs. IOH.
1.0
VF(OFF) = -3.0 to 0.8 V
IOUT = 100 mA
0.8
VCC = 15 to 30 V
VEE = 0 V
0.6
0.4
0.2
0
-40 -20 0 20 40 60 80 100
TA – TEMPERATURE – °C
1.0
0.8
0.6
0.4
VF(OFF) = -3.0 to 0.8 V
0.2
VOUT = 2.5 V
VCC = 15 to 30 V
VEE = 0 V
0
-40 -20 0 20 40 60
80 100
TA – TEMPERATURE – °C
5
VF(OFF) = -3.0 to 0.8 V
VCC = 15 to 30 V
4 VEE = 0 V
3
2
1
100 °C
25 °C
-40 °C
0
0 0.2 0.4 0.6 0.8 1.0
IOL – OUTPUT LOW CURRENT – A
Figure 4. VOL vs. Temperature.
Figure 5. IOL vs. Temperature.
Figure 6. VOL vs. IOL.
1-203