5
IEC/EN/DIN EN 60747-5-2 Insulation Characteristics
Description
Installation classification per DIN VDE
0110/1.89, Table 1
for rated mains voltage ≤ 150 Vrms
for rated mains voltage ≤ 300 Vrms
for rated mains voltage ≤ 600 Vrms
Climatic Classification
Pollution Degree (DIN VDE 0110/1.89)
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b*
VIORM x 1.875 = VPR, 100% Production
Test with tm = 1 sec,
Partial discharge < 5 pC
Input to Output Test Voltage, Method a*
VIORM x 1.5 = VPR, Type and Sample
Test, tm = 60 sec,
Partial discharge < 5 pC
Highest Allowable Overvoltage*
(Transient Overvoltage tini = 10 sec)
Safety-Limiting Values – Maximum Values
Allowed in the Event of a Failure, Also
See Figure 37, Thermal Derating Curve.
Case Temperature
Input Current
Output Power
Insulation Resistance at TS, VIO = 500 V
Symbol
VIORM
VPR
VPR
VIOTM
TS
IS, INPUT
PS, OUTPUT
RS
HCPL-3150#060
I-IV
I-III
55/100/21
2
630
1181
945
6000
175
230
600
≥ 109
HCPL-315J** Unit
I-IV
I-III
I-II
55/100/21
2
891
Vpeak
1670
Vpeak
1336
6000
Vpeak
Vpeak
175
°C
400
mA
1200
mW
≥ 109
Ω
**Approval Pending.
*Refer to the front of the optocoupler section of the current Catalog, under Product Safety Regulations section IEC/EN/DIN EN
60747-5-2, for a detailed description of Method a and Method b partial discharge test profiles.
Note: Isolation characteristics are guaranteed only within the safety maximum ratings which must be ensured by protective circuits