Absolute Maximum Ratings
Storage Temperature ................................................. -65°C to +150°C
Operating Temperature ............................................... -55°C to +125°C
Lead Solder Temperature ................................................ 260°C for 10 s
1.6 mm below seating plane
Forward Input Current – II (each channel) ................................. 60 mA2
Reverse Input Current ................................................................. 60 mA
Supply Voltage – VCC ....................................... 7 V (1 Minute Maximum)
Enable Input Voltage – VE (each channel) ...................................... 5.5 V
Not to exceed VCC by more than 500 mV
Output Collector Current – IO (each channel) ............................. 25 mA
Output Collector Power Dissipation (each channel) ................... 40 mW
Output Collector Voltage – VO (each channel) ................................... 7 V
Total Package Power Dissipation .............................................. 564 mW
Input Power Dissipation (each channel) ................................... 168 mW
Schematic
A 0.1 µF BYPASS CAPACITOR
MUST BE CONNECTED BETWEEN
PINS 10 AND 15 (SEE NOTE 1).
ESD Classification
(MIL-STD-883, Method 3015) .............................................. (∆), Class 1
Recommended Operating Conditions
Parameter
Symbol Min. Max. Units
Input Current, Low Level
Input Current, High Level*
Supply Voltage, Output
High Level Enable Voltage
Low Level Enable Voltage
Fan Out (@ RL = 4 kΩ)
IIL
0
250 µA
IIH
12.5
60
mA
VCC
4.5
5.5
V
VEH
2.0
VCC
V
VEL
0
0.8
V
N
5
TTL
Loads
Operating Temperature
TA
-55
125
°C
*12.5 mA condition permits at least 20% guardband for optical coupling variation. Initial