E6833A Datasheet, PDF (4/6 Pages) Agilent(Hewlett-Packard) – Wireless Communications Test Set | |||
|
◁ |
Occupied bandwidth
Dynamic Power Measurement
Measurement method
Input level range
Measurement accuracy
Measures the bandwidth that
contains 99.0% of the total
integrated power of the
transmitted signal centered on
the selected reverse channel
+5 to +28 dBm/1.23 MHz
±60 kHz for 99.0% total
integrated power
Tx spurious emissions
Measurement method
Input level range
Measurement offsets
Frequencies < 1000 MHz
Frequencies > 1000 MHz
Measurement bandwidth
Carrier
Offsets
Measurement accuracy
±885 kHz, ±1.25 MHz
±1.98 MHz
Residual noise ï¬oor
±885 kHz, ±1.25 MHz
±1.98 MHz offsets
Mobile pass/fail limits
Auto mode
Frequencies < 1000 MHz
Frequencies > 1000 MHz
Manual mode
Measures the active carrier
power in a 1.23 MHz bandwidth,
then measures the power in a
30 kHz bandwidth at two offsets
above and below the active
carrier and displays the ratio
of the offset powers to the
active carrier power in dBc
+0 to +30 dBm/1.23 MHz
±885 kHz, ±1.98 MHz
±1.25 MHz, ±1.98 MHz
1.23 MHz ï¬at channel ï¬lter
30 kHz synchronously tuned,
ï¬ve-pole ï¬lter with approximately
Gaussian shape
< ±0.35 dB, typically < ±0.15 dB
< ±0.6 dB, typically < ±0.25 dB
< â73 dBc/30 kHz BW
< â75 dBc/30 kHz BW
â42 dBc/30 kHz for
±885 kHz offsets
â54 dBc/30 kHz for
±1.98 MHz offsets
â42 dBc/30 kHz for
±1.25 MHz offsets
â50 dBc/30 kHz for
±1.98 MHz offsets
Settable from â10 to â65 dBc
with 0.01 dB resolution
Measurement method
Captures a user-deï¬ned trace
consisting of 5, 10, or 20 ms
duration power steps with
user-deï¬ned step size produced
by a test mode in the device
under test. Measures the total
power in each step period in a
1.23 MHz bandwidth centered
on the reverse channel center
frequency
Input level range
â61 to +28 dBm/1.23 MHz
Amplitude capture range
With 4 dB crest < ±2 dB of
expected power
Measurement accuracy1 (within +2 to â45 dB of expected power)
â61 to +28 dBm/1.23 MHz < ±0.7 dB, typically < ±0.2 dB
Measurement accuracy1 (within 45 dB of expected power with
< 48 hours warm-up before self alignment initiation)
â59 to +28 dBm/1.23 MHz < ±0.7 dB, typically < ±0.3 dB
â65 to < â59 dBm/1.23 MHz < ±0.8 dB, typically < ±05 dB
Measurement repeatability
Typically < ±0.05 dB for returning
to the same level and frequency
with no temperature change and
insigniï¬cant time change
Trigger setup
Sources external, fall, rise
Trigger
pulse
User speciï¬ed
maximum power
Step size
Step duration
1. Additional accuracy error when using RF OUT ONLY port is < ±0.1 dB.
4
|
▷ |