English
Language : 

E6833A Datasheet, PDF (3/6 Pages) Agilent(Hewlett-Packard) – Wireless Communications Test Set
RF Analyzer
Reverse Traffic Channel Suite
Frequency
Frequency range in ch annel numbers
US cellular band
1-799, 991-1023, 1024-1323
(815.04-848.97 MHz)
US PCS band
0-1199 (1850-1910 MHz)
Korean PCS band
0-599 (1750-1780 MHz)
Japan CDMA band
1-799, 801-1039, 1041-1199,
1201-1600
(887.0125-924.9875 MHz)
IMT-2000 band
0-1199 (1920-1979.950 MHz)
NMT-450 band
1-400, 472-871, 1039-1473,
1792-2016 (approx 410-484 MHz)
Secondary 800 band
0-719, 720-919
(806-824, 896-901 MHz)
US PCS 1900 band
0-1299 (1850-1915 MHz)
AWS band
0-899 (1710-1755 MHz)
Amplitude
Triggering this measurement suite results in the capture of
one block of samples from which is derived the channel power,
occupied bandwidth, and Tx spurious emissions parameters.
Trigger setup
Sources
External, immediate,
RF generator ARB
Channel power measurement
Measurement method
Measurement interval
Measurement range
Measurement accuracy
–61 to +28 dBm/1.23 MHz
Measurement repeatability
Measures the total power in a
1.23 MHz bandwidth centered
on the reverse channel center
frequency
1.25 ms for cdma2000 or
1.67 ms for 1xEV-DO
–61 dBm/1.23 MHz to
+28 dBm/1.23 MHz
< ±0.7 dB, typically < ±0.2 dB
Typically < ±0.05 dB
Input level range
Channel power
Peak input power
Self alignment validity
–61 dBm/1.23 MHz to
+28 dBm/1.23 MHz
–61 dBm/1.23 MHz to
+37 dBm/1.23 MHz
< ±10 °C change and < 30 days
from last self alignment
Modulation quality measurement
Input frequency ranges
Same as RF analyzer
Measurement chip rate
1.2288 Mcps
Measurement method
IS-95 or cdma2000 RC1: single
code rho
Input level range
Average power –25 to +37 dBm/
1.23 MHz
Modulation quality measurement range
(for signals with < ±1 kHz frequency error)
IS-95, RC1
0.40 to 1.00 rho
Measurement interval
1.042 ms (5 Walsh symbols)
Modulation quality measurement accuracy
IS-95, RC1 rho
< ±0.003 + residual error for
0.8 < rho < 1.0
Modulation quality measurement residuals
rho
> 0.999
Frequency error
±2 Hz plus timebase error
Measurement results
rho, frequency error, phase error,
magnitude error, carrier
feedthrough
3