English
Language : 

HMC601LP4 Datasheet, PDF (1/8 Pages) Hittite Microwave Corporation – 75 dB, FAST SETTLING, LOGARITHMIC DETECTOR / CONTROLLER 10 - 4000 MHz
HMC601LP4 / 601LP4E
v01.0509
75 dB, FAST SETTLING, LOGARITHMIC
DETECTOR / CONTROLLER 10 - 4000 MHz
12
12 - 10
Typical Applications
Features
The HMC601LP4(E) is ideal for IF and RF
applications in:
• Cellular/PCS/3G
• WiMAX, WiBro & Fixed Wireless
• Power Monitoring & Control Circuitry
• Receiver Signal Strength Indication (RSSI)
• Automatic Gain & Power Control Circuits
Functional Diagram
Wide Dynamic Range: up to 75 dB
Fast Pulse Response: 15/34ns (Rise/Fall Time)
Flexible Supply Voltage: +2.7V to +5.5V
Power-Down Mode
Excellent Stability over Temperature
Compact 4x4mm Leadless SMT Package
General Description
The HMC601LP4(E) Logarithmic Detector/Controller
converts RF signals at its input, to a proportional DC
voltage at its output. The HMC601LP4(E) employ
a successive compression topology which delivers
extremely high dynamic range and conversion
accuracy over a wide input frequency range. As
the input power is increased, successive amplifiers
move into saturation one by one creating an accurate
approximation of the logarithm function. The output of
a series of square law detectors is summed, converted
into voltage domain and buffered to drive the LOGOUT
output. For detection mode, the LOGOUT pin is
shorted to the VSET input, and will provide a nominal
logarithmic slope of 19mV/dB and an intercept of
-100dBm. The HMC601LP4(E) can also be used in the
controller mode where an external voltage is applied to
the VSET pin, to create an AGC or APC feedback loop.
The HMC601LP4(E) provides a 15/34ns (rise/fall time)
response time enabling RF burst detection to a pulse
rate beyond 20 MHz.
Electrical Specifications, TA = +25C, PWD = 0V, Vcc1, Vcc2 = +3.3V [1]
Parameter
Typ.
Typ.
Typ.
Typ.
Input Frequency
50
100
500
900
±3 dB Dynamic Range
74
74
74
74
±3 dB Dynamic Range Center
-31
-31
-31
-31
±1 dB Dynamic Range
68
68
69
69
Output Slope
19.5
19.4
19.2
19.1
Output Intercept
-99
-99
-100
-100
Temperature Sensitivity @ -10 dBm Input [2]
-4.2
-3.8
-3.5
-2.4
[1] Detector mode measurements; LOGOUT (Pin 17) is shorted to VSET (Pin 16).
[2] Measured from TA = -40C to TA = +85C
Typ.
1900
70
-31.5
67
19.0
-98
-0.8
Typ.
2500
68
-31.5
65
19.4
-96
-0.8
Typ.
3500
54
-27
47
20.9
-85
-4.4
Parameter
RF Input (INP)
Return Loss
LOGOUT Interface
Conditions
F = 10 - 4000 MHz, Zo = 50Ω, See plot
Min.
Typ.
10
Open Loop Impedance
(Simulated)
12
Typ.
4000
52
-23
46
19.6
-79
-3.5
Units
MHz
dB
dBm
dB
mV/dB
dBm
mdB/°C
Max.
Units
dB
kΩ
For price, delivery, and to place orders, please contact Hittite Microwave Corporation:
20 Alpha Road, Chelmsford, MA 01824 Phone: 978-250-3343 Fax: 978-250-3373