FH25-21S-0.3SH Datasheet, PDF (3/8 Pages) Hirose Electric – 0.3 mm Contact Pitch, 0.9 mm above the board, Flexible Printed Circuit ZIF Connectors. | |||
|
◁ |
BOperation and Precautions
Operation
1.FPC insertion procedure. Connector installed on
the board.
1 Lift up the actuator. Use thumb or index finger.
Precautions
1 Do not apply excessive force or use any type of tool to operate the
actuator.
2 Fully insert the FPC in the connector parallel to mounting surface, with
the exposed conductive traces facing down.
2 The connector will assure reliable performance when the actuator is
open to 130Ëmaximum. Do not exceed this angle, as this may cause
permanent damage to the connector.
FPC conductor
surface
(Bottom side)
130°
3 Rotate down the actuator until firmly closed. It is critical that the
inserted FPC is not moved and remains fully inserted.
3 Exercise caution when applying upward force to the connected FPC.
FPC conductor surface on opposite side.
2.FPC removal
1 Lift up the actuator.
Carefully withdraw the FPC.
3
|
▷ |