BOperation and Precautions
Operation
1.FPC insertion procedure. Connector installed on
the board.
1 Lift up the actuator. Use thumb or index finger.
Precautions
1 Do not apply excessive force or use any type of tool to operate the
actuator.
2 Fully insert the FPC in the connector parallel to mounting surface, with
the exposed conductive traces facing down.
2 The connector will assure reliable performance when the actuator is
open to 130˚maximum. Do not exceed this angle, as this may cause
permanent damage to the connector.
FPC conductor
surface
(Bottom side)
130°
3 Rotate down the actuator until firmly closed. It is critical that the
inserted FPC is not moved and remains fully inserted.
3 Exercise caution when applying upward force to the connected FPC.
FPC conductor surface on opposite side.
2.FPC removal
1 Lift up the actuator.
Carefully withdraw the FPC.