English
Language : 

CD22101 Datasheet, PDF (7/13 Pages) Harris Corporation – CMOS 4 x 4 x 2 Crosspoint Switch with Control Memory
FUNCTION
A
Switch ON
1
Switch OFF
1
No Change
X
1 = High Level
CD22101, CD22102
CONTROL TRUTH TABLE FOR CD22101
ADDRESS
B
C
D
1
1
1
1
1
1
X
X
X
0 = Low Level
STROBE DATA
SELECT
1
1
15 (X4Y4) and 15’ (X4’Y4’)
1
0
15 (X4Y4) and 15’ (X4’Y4’)
0
X
XXXX
X = Don’t Care
CONTROL TRUTH TABLE FOR CD22102
ADDRESS
FUNCTION
A
B
C
D
KA
Switch ON
1
1
1
1
1
KB
SELECT
0
15 (X4Y4) and 15’ (X4’Y4’)
Switch OFF
1
1
1
1
0
1
15 (X4Y4) and 15’ (X4’Y4’)
All Switches
X
X
X
X
1
1
All
OFF (Note 5)
No Change
X
X
X
X
0
0
XXXX
1 = High Level
0 = Low Level
X = Don’t Care
NOTE:
5. In the event that KA and KB are changed from levels 1, 1 to 0, 0 KB should not be allowed to go to 0 before KA,
otherwise a switch which was off will inadvertently be turned on.
Metallization Mask Layout
Dimensions in parenthesis are in millimeters and are derived
from the basic inch dimensions as indicated. Grid graduations
are in mils (10-3 inch).
4-199