English
Language : 

S11155-2048-01_15 Datasheet, PDF (5/8 Pages) Hamamatsu Corporation – CCD linear image sensors
CCD linear image sensors
S11155-2048-01, S11156-2048-01
Timing chart
Non-MPP operation
1 line output period
Tpwar
Tinteg
(electronic shutter: closed)
(electronic shutter: open)
ARG
REGH, REGL (REGH=-4 V, REGL=-6.5 V)
Tpwv Tovr
TG
Tpwh, Tpws
P1H
1
2
3..2067
2068 2069
2070...
N*
P2H
SG
Tpwr
RG
OS
D1
D2
D19 D20
D3..D10, S1...S2048, D11..D18
Normal readout period
Dummy readout period
* Apply clock pulses to the specified terminals during the period of dummy readout.
Set the total number of clock pulses N, according to the integration time.
Parameter
Symbol
Min.
Typ.
ARG
Pulse width
Rise and fall times
Tpwar
1
Tprar, Tpfar
200
-
-
TG
Pulse width
Tpwv
2
Rise and fall times
Tprv, Tpfv
20
-
-
Pulse width
Tpwh
50
100
P1H, P2H*20
Rise and fall times
Tprh, Tpfh
10
-
Duty ratio
-
40
50
Pulse width
Tpws
50
100
SG
Rise and fall times
Tprs, Tpfs
10
-
Duty ratio
-
40
50
RG
Pulse width
Tpwr
5
Rise and fall times
Tprr, Tpfr
5
15
-
TG - P1H
Overlap time
Tovr
1
2
Integration time
Tinteg
2
-
*20: Symmetrical clock pulses should be overlapped at 50% of maximum pulse amplitude.
Max.
-
-
-
-
-
-
60
-
-
60
-
-
-
-
KMPDKMCP0DC3038822EBE
Unit
μs
ns
μs
ns
ns
ns
%
ns
ns
%
ns
ns
μs
μs
5