RECOMMENDED OPERATING CONDITIONS(2)
Parameter
Symbol
Condition
Value
Unit
Min.
Typ.
Max.
Control input voltage
VI
—
0
Power
supply
control
section
Output current
Backup current
IO1 to IO3
—
- 50
IO4
—
- 10
IBATT1
—
—
CLR input pulse width
TCLR
—
200
OFF input pulse width
TOFF CT3 = 2.2 mF, RT3 = 1MW
10
ON2 input pulse width
TON2
—
10
ON setting
time setup
Capacitance
CT1
—
—
Resistance
RT1
—
—
Momentary
Capacitance
CT3
—
—
power - loss
time setup
Resistance
RT3
—
—
Speaker
amplifier
section
Control input voltage
Amplifier input voltage
Load resistance
VI
—
0
VIN
—
0.3
RL
—
8
Gain setting range
AV
When Non - INV input
6
—
VCC
V
—
—
mA
—
—
mA
—
200
mA
—
—
ns
—
—
ms
—
—
ms
1.5
—
mF
1
—
MW
2.2
—
mF
1
—
MW
—
VCC
V
—
VCC - 0.8
V
32
200
W
24
36
dB
When INV input
- 26
- 20
36
dB
Sounder
section
Control input voltage
Output current
Voltage
monitoring
section
RESET output current
Reset/hold time setup capacitance
Clock monitoring time setup
capacitance
Clock monitoring time setting
VI
IO1
IO2
IO3
IOL, IOH
CTP
CTW
TWD
—
Duty = 50%
Duty = 50%
Duty = 50%
—
—
—
—
0
—
VCC
V
—
—
200
mA
—
—
100
mA
—
—
50
mA
-3
—
3
mA
0.001
—
10
mF
0.001
—
1
mF
0.1
—
1500
ms
Note: The recommended operating conditions are the recommended values guaranteeing normal LSI operations. The specified
values for electrical characteristics are guaranteed when the conditions in the ”Condition” column, as well as the recommended
operating conditions, are met.