|
MB3829 Datasheet, PDF (15/24 Pages) Fujitsu Component Limited. – System Power Supply IC for Mobile Telephone | |||
|
◁ |
MB3829
4. Voltage monitoring section
Parameter
Symbol
Condition
Min.
(OUT1 = +3.0V, TA = +25°C)
Value
Unit
Typ.
Max.
Detection voltage
VSL
OUT1 fall
2.70
2.75
2.81
V
VSH
OUT1 rise
2.76
2.81
2.87
V
Detection voltage hysteresis width
CK input threshold voltage
CK input hysteresis width
Inhibit input voltage
VSHYS
VCIH
VCIL
VCHYS
VIIH
VSH - VSL
-
-
-
-
35
65
95
mV
0.6
1.2
1.8
V
0.4
0.9
1.4
V
0.1
0.3
0.6
V
1.8
â
â
V
VIIL
-
â
â
0.8
V
Input current
CK
IHB
Reset output voltage
Reset output minimum voltage
Power - on reset hold time
Watchdog timer monitoring time
Watchdog timer reset time
Clock input pulse width
Clock input pulse cycle
IINH
IINL
VOH
VOL
VCCL
tPR
tWD
tWR
tCKW
tCKT
VIN = OUT1
â
VIN = GND
- 1.0
IRESET = - 3mA
2.5
IRESET = +3mA
â
IRESET = +50mA
â
CTP = 0.1mF
25
CTW=0.01mF, CTP=0.1mF
8
CTP = 0.1mF
1.5
-
* 500
-
* 20
0
0
2.8
0.12
0.8
70
16
5
â
â
1.0
mA
â
mA
â
V
0.4
V
1.2
V
115
ms
24
ms
8.5
ms
â
ns
â
ms
RESET rise time
RESET fall time
Delay time from OUT1
tr *1
tr *1
TPD
CL = 50pF
CL = 50pF
-
* 2.0
*â
*â
OUT1 input pulse width
TPI
1.2V to 2.5V * 16
*1: The voltage range prevailing during RESET output rise/fall time measurement is from 10% to 90%
*: Guaranteed by design
â
500
ns
â
500
ns
2
20
ms
â
â
ms
15
|
▷ |