English
Language : 

MB3782_1 Datasheet, PDF (12/27 Pages) Fujitsu Component Limited. – ASSP Power Supplies BIPOLAR Switching Regulator Controller
MB3782
s ABSOLUTE MAXIMUM RATINGS
Parameter
Symbol
Condition
Power supply voltage
Error amp input voltage
Dead time control input voltage
Control input voltage
Collector output voltage
Collector output current
Allowable loss
Operating temperature
Storage temperature
VCC
VIN
Vdt
VCTL
VOUT
IOUT
PD*1
Top
Tstg
—
—
—
—
—
—
SOP Version
Ta ≤ +25°C
DIP Version
—
—
Rating
Min
Max
(Ta = +25°C)
Unit
—
20
V
–0.3
+10
V
–0.3
+2.8
V
–0.3
+20
V
—
20
V
—
75
mA
—
740*2
mW
—
1110
–30
+85
°C
–55
+125
°C
*1: For operation in conditions where Ta > +25°C, the SOP version should be derated by 7.4 mW/°C, and the DIP
version should be derated by 11.1 mW/°C.
*2: When mounted on a 4 cm-square dual-sided epoxy board.
WARNING: Semiconductor devices can be permanently damaged by application of stress (voltage, current,
temperature, etc.) in excess of absolute maximum ratings. Do not exceed these ratings.
s RECOMMENDED OPERATING CONDITIONS
Parameter
Symbol Condition
Min
Value
Typ
Unit
Max
Power supply voltage
Error amp input voltage
VCC
—
3.6
6.0
18.0
V
VIN
—
1.05
—
1.45
V
Control input voltage
Collector output voltage
VCTL
—
VOUT
—
0
—
18
V
—
—
18
V
Collector output current
IOUT
—
0.3
—
50
mA
Reference voltage output current
IREF
—
–3
–1
0
mA
Timing capacitance
CT
—
150
—
15000
pF
Timing resistance
RT
—
5.1
—
100
kΩ
Oscillator frequency
fOSC
—
1
—
500
kHz
Operating temperature
Top
—
–30
+25
85
°C
WARNING: The recommended operating conditions are required in order to ensure the normal operation of the
semiconductor device. All of the device’s electrical characteristics are warranted when the device is
operated within these ranges.
Always use semiconductor devices within their recommended operating condition ranges. Operation
outside these ranges may adversely affect reliability and could result in device failure.
No warranty is made with respect to uses, operating conditions, or combinations not represented on
the data sheet. Users considering application outside the listed conditions are advised to contact their
FUJITSU representatives beforehand.
12