Terminology and guidelines
3.6 Relationship between ratings and operating requirements
Operating or handling rating (min.)
Operating requirement (min.)
Operating requirement (max.)
Operating or handling rating (max.)
Fatal
range
- Probable permanent failure
Limited
operating
range
- No permanent failure
- Possible decreased life
- Possible incorrect operation
Normal
operating
range
- No permanent failure
- Correct operation
Limited
operating
range
- No permanent failure
- Possible decreased life
- Possible incorrect operation
Fatal
range
- Probable permanent failure
Handling range
- No permanent failure
ââ
â
ry 3.7 Guidelines for ratings and operating requirements
a Follow these guidelines for ratings and operating requirements:
in ⢠Never exceed any of the chipâs ratings.
⢠During normal operation, donât exceed any of the chipâs operating requirements.
⢠If you must exceed an operating requirement at times other than during normal
operation (for example, during power sequencing), limit the duration as much as
lim possible.
3.8 Definition: Typical value
e A typical value is a specified value for a technical characteristic that:
r ⢠Lies within the range of values specified by the operating behavior
⢠Given the typical manufacturing process, is representative of that characteristic
P during operation when you meet the typical-value conditions or other specified
conditions
Typical values are provided as design guidelines and are neither tested nor guaranteed.
3.8.1 Example 1
This is an example of an operating behavior that includes a typical value:
Symbol
IWP
Description
Min.
Digital I/O weak 10
pullup/pulldown
current
Typ.
70
Max.
130
Unit
µA
K40 Sub-Family Data Sheet Data Sheet, Rev. 1, 11/2010.
Freescale Semiconductor, Inc.
Preliminary
9
|
▷ |