Memory Map and Registers Description
4.2.3.6 Y coordinate stabilization time
This 16-bit value holds the number needed in micro-seconds for the signals required for a Y coordinate scanning to stabilize.
The value is calculated automatically as part of the calibration process but can be written through serial communication to
simplify factory configuration of devices.
Bit
15 14 13 12 11 10 9
8
7 65 4
3
2
1
0
Field
YCTIMESETMSB
YCTIMESETLSB
Signal
Description
15-8
Most significant byte for the Y coordinates stabilization delay.
Y Coordinate
stabilization MSB
7-0
Least significant byte for the Y coordinates stabilization delay
Y Coordinate
stabilization LSB
4.2.3.7 Z coordinate stabilization time
This 16-bit value holds the number needed in micro-seconds for the signals required for the pressure coordinate scanning to
stabilize. The value is calculated automatically as part of the calibration process, but can be written through serial
communication to simplify factory configuration of devices.
Bit
15 14 13 12 11 10 9
8
7 65 4
3
2
1
0
Field
ZTIMESETMSB
ZTIMESETLSB
Signal
Description
15-8
Most significant byte for the two-touch signals stabilization delay.
Pressure
stabilization MSB
7-0
Least significant byte for the two-touch signals stabilization delay
Pressure
stabilization LSB
4.2.3.8 Display horizontal resolution
Determines the resolution for the X coordinates. It is important to configure this value properly before a calibration is executed.
Values written to this register have no effect until after both horizontal and vertical resolutions have been written. Writes to these
registers reset the device calibration.