Appendix A Electrical Characteristics and Timing Specifications
A.7 Supply Current Characteristics
Table A-8. Supply Current Characteristics
Num C
Parameter
2
Run supply current measured at
1
P
(CPU clock = 2 MHz, fBus = 1 MHz)
Run supply current2 measured at
2
P
(CPU clock = 16 MHz, fBus = 8 MHz)
Run supply current3 measured at (CPU
3
P clock = 40 MHz, fBus = 20 MHz)
Stop2 mode supply current
4P
Symbol
RIDD
RIDD
RIDD
S2IDD
VDD
(V)
Typ1
5 0.750
3 0.570
5 4.90
3 3.50
5 16.8
3 11.5
5 0.900
3 0.720
Max
0.950
0.770
5.10
3.70
18.5
12.5
18.0
60
17.0
50
Unit
Temp
(°C)
mA –40 to 125°C
mA –40 to 125°C
mA –40 to 125°C
–40 to 85°C
μA –40 to 125°C
–40 to 85°C
μA –40 to 125°C
Stop3 mode supply current
5P
S3IDD
20.0
5 0.975 90
19.0
3 0.825 85
–40 to 85°C
μA –40 to 125°C
–40 to 85°C
μA –40 to 125°C
6
C RTI adder to stop2 or stop34
5
300
500
500
nA
–40 to 85°C
–40 to 125°C
S23I
DDRTI
3
300
500
500
nA
–40 to 85°C
–40 to 125°C
5
110
180
μA –40 to 125°C
7
C LVD adder to stop3 (LVDE = LVDSE = 1) S3IDDLVD
3
90
160
μA –40 to 125°C
Adder to stop3 for oscillator enabled
8
C (OSCSTEN =1)5
S3IDDOSC
5,3
5
8
μA –40 to 125°C
1 Typical values are based on characterization data at 25°C unless otherwise stated. See Figure A-5 through Figure A-7 for
typical curves across voltage/temperature.
2 All modules except ADC enabled, but not active. ICG configured for FBE. Does not include any DC loads on port pins.
3 All modules except ADC active, ICG configured for FBE and does not include any DC loads on port pins
4 Most customers are expected to find that auto-wakeup from stop2 or stop3 can be used instead of the higher current wait
mode. Wait mode typical is 500 μA at 5 V with fBus = 1 MHz.
5 Values given under the following conditions: low range operation (RANGE = 0) with a 32.768 kHz crystal, low power mode
(HGO = 0), clock monitor disabled (LOCD = 1).
MC9S08AW60 Data Sheet, Rev 2
Freescale Semiconductor
291