FUNCTIONAL DEVICE OPERATION
OPERATIONAL MODES
Table 19. Interrupt Timer
Bits 543
Interrupt Period
000
32 ms
001
64 ms
010
128 ms
011
256 ms
100
512 ms
101
1.024 s
110
2.048 s
111
No interrupt wake-up
The scan timer sets the polling period between input
switch reads in Sleep mode. The period is set in the sleep
command and may be set to 000 (no period) to 111 (64 ms).
In Sleep mode when the scan timer expires, inputs will
behave as programmed prior to sleep command. The 33972
will wake up for approximately 125 µs and read the switch
inputs. At the end of the 125 µs, the input switch states are
compared with the switch state prior to sleep command.
When switch state changes are detected, an interrupt (when
enabled; refer to wake-up / interrupt command description on
page 14) is generated and the device enters Normal mode.
Without switch state changes, the 33972 will reset the scan
timer, inputs become tri-state, and the Sleep mode continues
until the scan timer expires again.
Table 20 shows the programmable settings of the Scan
timer.
Table 20. Scan Timer
Bits 210
000
001
010
011
100
101
110
111
Scan Period
No Scan
1.0 ms
2.0 ms
4.0 ms
8.0 ms
16 ms
32 ms
64 ms
Note The interrupt and scan timers are disabled in the
Normal mode.
Figure 5, page 9, is a graphical description of how the
33972 device exits Sleep mode and enters Normal mode.
Notice that the device will exit Sleep mode when the interrupt
timer expires or when a switch change of state occurs. The
falling edge of INT triggers the MCU to wake from Sleep state.
Figure 11 illustrates the current consumed during Sleep
mode. During the 125 µs, the device is fully active and switch
states are read. The quiescent current is calculated by
integrating the normal running current over scan period plus
approximately 60 µA.
II==VV//RRoor r0.027.207V0/1V00/o1h0m0=Ω2=.72m.7A mA
IonIu1npt2upo5tfus µ3at2scstmiaovcseutftiovoref12f3o52rums s
II=V/RRoorr6mV/100ohm = 60 uA
6.0 mV/100 Ω=60 µA
Figure 11. Sleep Current Waveform
TEMPERATURE MONITOR
With multiple switch inputs closed and the device
programmed with the wetting current timers disabled,
considerable power will be dissipated by the IC. For this
reason temperature monitoring has been implemented. The
temperature monitor is active in the Normal mode only. When
the IC temperature is above the thermal limit, the temperature
monitor will do all of the following:
• Generate an interrupt.
• Force all 16 mA pullup and pulldown current sources to
revert to 2.0 mA current sources.
• Maintain the 2.0 mA current source and all other
functionality.
• Set the thermal flag bit in the SPI output register.
The thermal flag bit in the SPI word will be cleared on rising
edge of CS provided the die temperature has cooled below
the thermal limit. When die temperature has cooled below
thermal limit, the device will resume previously programmed
settings.