English
Language : 

FWLF1524P2YXX Datasheet, PDF (7/11 Pages) Finisar Corporation. – 4 Gigabit RoHS Compliant CWDM SFP Transceiver
FWLF1524P2yxx SFP Product Specification – April 2012
Finisar
VIII. Digital Diagnostic Functions
All Finisar SFPs support the 2-wire serial communication protocol outlined in the SFP
MSA5. These SFPs use an Atmel AT24C01A 128 byte E2PROM with an address of A0h
(see table below for E2PROM contents). For details on interfacing with the E2PROM, see
the Atmel data sheet titled “AT24C01A/02/04/08/16 2-Wire Serial CMOS E2PROM.”6
Finisar’s CWDM SFPs also support extended diagnostic features as described in Finisar
Applications Note AN-2030, “Digital Diagnostic Monitoring Interface for Optical
Transceivers”7, and additional information is available in SFF standard titled: “Digital
Diagnostic Monitoring Interface for Optical Transceivers8 (SFF-8472 rev9.3). A
controller IC that monitors system parameters such as laser current, module temperature,
transmitter power, and received power is accessible at address A2H.
I2C clock speed, digital diagnostic accuracy and digital diagnostic range can be found in
the table below. Values in the table represent the worst-case values over temperature,
voltage, and life.
Parameter
I2C Clock Speed
Accuracy
Transceiver
Temperature
Transceiver Supply
Voltage
Tx Bias Curent
Tx Output Power
Received Average
Power
Range
Transceiver
Temperature
Transceiver Supply
Voltage
Tx Bias Current
Tx Output Power
Received Average
Power
Symbol Min Typ Max Units Notes/Conditions
0
100,000 Hz Bus can be driven blind
DDTemperature -5
DDVoltage
-3
DDBias
-10
DDTxPower
-3
DDRxPower
-3
+5
°C Case temperature
+3
%
+10
%
+3
dB 100% tested in production
over temp to 2 dB
+3
dB 100% tested in production
over temp to 2 dB
DDTemperature -10
DDVoltage
3.0
DDBias
0
DDTxPower
-10
DDRxPower
-25
80
°C
4.0
V
100 mA
+5
dBm
+1
dBm
Finisar Corporation April, 2012 Rev E
Page 7