English
Language : 

FAN1577A Datasheet, PDF (4/15 Pages) Fairchild Semiconductor – Dual Synchronous DC/DC Controller
Absolute Maximum Ratings
Stresses exceeding the absolute maximum ratings may damage the device. The device may not function or be
operable above the recommended operating conditions and stressing the parts to these levels is not recommended.
In addition, extended exposure to stresses above the recommended operating conditions may affect device
reliability. The absolute maximum ratings are stress ratings only. All voltage values, except differential voltages, are
given with respect to the network ground terminal. Stresses beyond those listed under Absolute Maximum Ratings
may cause permanent damage to the device.
Symbol
Parameter
VCC
BST1(or 2) –
CLN1(or 2)
Supply Voltage, VCC to GND
BST1(2) to CLN1(2)
CLN1(or 2) –
GND
CLN1(2) to GND for 100ns Transient
BST1(or 2) –
GND
BST1(2) to GND for 100ns Transient
DH1(or 2) –
CLN1(or 2)
CLN1(or 2),
DL1(or 2)
PGND
PGND to GND
ΘJA
TJ
TSTG
ESD
Thermal Resistance, Junction-Air
Operating Junction Temperature
Storage Temperature Range
Electrostatic Discharge
Protection Level
Human Body Model (HBM)
Charged Device Model (CDM)
Min.
-4
-0.3
-40
-65
Max.
16
16
18
30
16
VCC+0.3
±1
70
+125
+150
2
1
Unit
V
V
V
V
V
V
V
°C/W
°C
°C
kV
Recommended Operating Conditions
The Recommended Operating Conditions table defines the conditions for actual device operation. Recommended
operating conditions are specified to ensure optimal performance to the datasheet specifications. Fairchild does not
recommend exceeding them or designing to absolute maximum ratings.
Symbol
VCC
TA
Parameter
Supply Voltage
Operating Ambient Temperature
Min.
-40
Max.
+15
+85
Unit
V
°C
© 2010 Fairchild Semiconductor Corporation
FAN1577A • Rev. 1.0.0
4