English
Language : 

MN35 Datasheet, PDF (6/10 Pages) Extech Instruments Corporation. – Manual Ranging Mini MultiMeter
Meter Description
1. LCD Display
2. Hold button
3. Function switch
4. COM jack
5. 10A jack
6. Positive jack
Note: Tilt stand and battery
access is on the rear of unit.
Operating Instructions
Note: If “H” and a blank screen appear when the meter is turned on
the HOLD feature is active. Press the HOLD button to exit the
HOLD mode.
AC or DC Voltage Measurements
1. Insert the black test lead banana plug into the negative COM jack and
the red test lead banana plug into the positive V jack.
2. Turn the rotary switch to the highest VAC or VDC position.
3. Touch the test probes to the circuit under test and read the voltage on
the display.
4. Reset the function switch to successively lower positions to obtain a
higher resolution reading. If the polarity is reversed (DC voltage only),
the display will show (-) minus before the value.
6
MN35 V2.0 2/05