English
Language : 

XRT73R12_0710 Datasheet, PDF (86/89 Pages) Exar Corporation – TWELVE CHANNEL E3/DS3/STS-1 LINE INTERFACE UNIT
XRT73R12
TWELVE CHANNEL E3/DS3/STS-1 LINE INTERFACE UNIT
8.0 ELECTRICAL CHARACTERISTICS
REV. 1.0.3
SYMBOL
VDD
VIN
IIN
STEMP
ATEMP
Theta JA
Theta JC
MLEVL
ESD
TABLE 46: ABSOLUTE MAXIMUM RATINGS
PARAMETER
Supply Voltage
MIN
MAX
UNITS
-0.5
6.0
V
Input Voltage at any Pin
-0.5
5.5
V
Input current at any pin
100
mA
Storage Temperature
-65
Ambient Operating Temperature
-40
Thermal Resistance: Junction-to-Ambient
150
0C
85
0C
7.5
0C/W
Thermal Resistance: Junction-to-Case
0.5
0C/W
Exposure to Moisture
5
level
ESD Rating
2000
V
COMMENTS
Note 1
Note 1
Note 1
Note 1
Industrial Temp Grade
linear air flow 200ft/min
(See Note 3 below)
All conditions
EIA/JEDEC
JESD22-A112-A
Note 2
NOTES:
1. Exposure to or operating near the Min or Max values for extended period may cause permanent failure and impair
reliability of the device.
2. ESD testing method is per MIL-STD-883D,M-3015.7
3. Linear Air flow of 200 ft/min recommended for Industrial Applications. Theta JA = 9.4°C/W with 0 Lft /min, Theta JA
= 7.1 °C/W with 400Lft/min.
83