English
Language : 

XR18910 Datasheet, PDF (4/19 Pages) Exar Corporation – 8:1 Sensor Interface Analog Front End
XR18910
Electrical Characteristics (Continued)
TA = 25°C, VCC = 3.3V, VDD = 1.8V, RL = 10kΩ to 1.5V, G = 760, unless otherwise noted.
Symbol Parameter
Dynamic Performance
BW
-3dB bandwidth
SR
Slew rate
eNI
Input voltage noise, RTI
iN
eNP-P
XTALK
TS
TWAKE
Input current noise
Peak-to-peak noise
Crosstalk
Set-up time, 1% settling
Wake up time, 1% settling
Conditions
Min
G = 760
G=2
VOUT = 1VP-P, G = 2
f = 10Hz
f = 100Hz
f = 1kHz
f = 10Hz
f = 0.1 to 10Hz
Channel-to-channel, f = 1kHz
Analog ready after serial register finished write
Wake from ACK of SLEEP_OUT command
Typ
66
1300
1
75
46
35
0.6
2
90
3.5
9.6
Max Units
kHz
kHz
V/μs
nV/√Hz
nV/√Hz
nV/√Hz
fA/√Hz
μVP-P
dB
μs
μs
Digital Characteristics (CMOS)
Symbol Parameter
VIH
VIL
IIH
IIL
CLKF
Logic input HIGH
Logic input LOW
Input leakage HIGH
Input leakage LOW
Clock rate
Conditions
VI = VS
VI = 0
Min
Typ
Max Units
0.7 x VDD
0
-10
VDD
0.3 x VDD
10
0.4
V
V
μA
μA
MHz
I2C Bus Timing
TA = -40 to 85°C, VDD = 1.8 to 5V, unless otherwise noted.
Symbol Parameter
fSCL
TBUF
THD;STA
TSU;STA
THD;DAT
TVD;ACK
TVD;DAT
TSU;DAT
TLOW
THIGH
TF
TR
TSP
Operating frequency
Bus free time between STOP and
START
START condition hold time
START condition setup time
Data hold time
Data valid acknowledge
SCL LOW to data out valid
Data setup time
Clock LOW period
Clock HIGH period
Clock/data fall time
Clock/data rise time
Pulse width of spikes tolerance
Standard Mode
I2C-BUS
Min Max
0
100
4.7
4.0
4.7
0
0.6
0.6
250
4.7
4.0
300
1000
0.5
Fast Mode
I2C-BUS
Min Max
0
400
1.3
0.6
0.6
0
0.6
0.6
150
1.3
0.6
300
300
0.5
Units
kHz
μs
μs
μs
μs
μs
ns
ns
μs
μs
ns
ns
μs
REV1A
4/19