English
Language : 

XR18910 Datasheet, PDF (2/19 Pages) Exar Corporation – 8:1 Sensor Interface Analog Front End
XR18910
Absolute Maximum Ratings
Stresses beyond the limits listed below may cause
permanent damage to the device. Exposure to any Absolute
Maximum Rating condition for extended periods may affect
device reliability and lifetime.
Analog supply voltage (VCC)........................................... 0V to 5.5V
Digital supply voltage (VDD)............................................ 0V to 5.5V
Digital input/output (VDDIO)............................................. 0V to 5.5V
VIN......................................................................................0 to VCC
Differential input voltage (current limit of 10mA)....................... VCC
ESD rating (HBM - human body model)....................................4kV
Operating Conditions
Analog supply voltage range..................................... 2.7V to 5.25V
Digital supply voltage range........................................1.7V to 5.25V
Operating temperature range....................................-40°C to 85°C
Junction temperature............................................................. 150°C
Storage temperature range......................................-65°C to 150°C
Lead temperature (soldering, 10s).........................................260°C
Package thermal resistance θJA.......................................50°C/W(1)
NOTE:
1. JEDEC standard, multi-layer test boards, still air.
REV1A
2/19