English
Language : 

XR19L222 Datasheet, PDF (37/53 Pages) Exar Corporation – TWO CHANNEL INTEGRATED UART AND RS-232 TRANSCEIVER
XR19L222
REV. 1.0.0
TWO CHANNEL INTEGRATED UART AND RS-232 TRANSCEIVER
These bits are used to program desired trigger levels when trigger Table-D is selected. FCTR bit-7 selects
between programming the RX Trigger Level (a logic 0) and the TX Trigger Level (a logic 1).
4.17 RX/TX FIFO Level Count Register (FC) - Read-Only
This register is accessible when LCR = 0xBF. Note that this register is not identical to the FIFO Level Count
Register which is located in the general register set when FCTR bit-6 = 1 (Scratchpad Register Swap). It is
suggested to read the FIFO Level Count Register at the Scratchpad Register location when FCTR bit-6 = 1.
See Table 12.
FC[7:0]: RX/TX FIFO Level Count
Receive/Transmit FIFO Level Count. Number of characters in Receiver FIFO (FCTR[7] = 0) or Transmitter
FIFO (FCTR[7] = 1) can be read via this register. Reading this register is not recommended when transmitting
or receiving data.
4.18 Feature Control Register (FCTR) - Read/Write
This register controls the XR16V2751 new functions that are not available in ST16C2450 or ST16C2550.
FCTR[1:0]: RTS Hysteresis
User selectable RTS# hysteresis levels for hardware flow control application. After reset, these bits are set to
“0” to select the next trigger level for hardware flow control. See Table 13 for more details.
FCTR[2]: IrDa RX Inversion
• Logic 0 = Select RX input as encoded IrDa data (Idle state will be LOW).
• Logic 1 = Select RX input as inverted encoded IrDa data (Idle state will be HIGH).
FCTR[3]: Reserved
For proper functionality, this bit should be a logic 0.
FCTR[5:4]: Transmit/Receive Trigger Table Select
See Table 10 for more details.
TABLE 14: TRIGGER TABLE SELECT
FCTR
BIT-5
FCTR
BIT-4
TABLE
0
0 Table-A (TX/RX)
0
1 Table-B (TX/RX)
1
0 Table-C (TX/RX)
1
1 Table-D (TX/RX)
FCTR[6]: Scratchpad Swap
• Logic 0 = Scratch Pad register is selected as general read and write register. ST16C550 compatible mode.
• Logic 1 = FIFO Level Count register (Read-Only), Enhanced Mode Select Register (Write-Only). Number of
characters in transmit or receive FIFO can be read via scratch pad register when this bit is set. Enhanced
Mode Select Register is selected when it is written into.
FCTR[7]: Programmable Trigger Register Select
If using both programmable TX and RX trigger levels, TX trigger levels must be set before RX trigger levels.
• Logic 0 = Registers TRG and FC selected for RX.
• Logic 1 = Registers TRG and FC selected for TX.
37