English
Language : 

XR16L784 Datasheet, PDF (37/52 Pages) Exar Corporation – HIGH PERFORMANCE 2.97V TO 5.5V QUAD UART
áç
REV. 1.2.0
XR16L784
HIGH PERFORMANCE 2.97V TO 5.5V QUAD UART
TABLE 17: 16 SELECTABLE HYSTERESIS LEVELS WHEN TRIGGER TABLE-D IS SELECTED
FCTR BIT-3
FCTR BIT-2
FCTR BIT-1
FCTR BIT-0
RTS/DTR HYSTERESIS
(CHARACTERS)
0
0
0
0
0
0
0
0
1
+/- 4
0
0
1
0
+/- 6
0
0
1
1
+/- 8
0
1
0
0
+/- 8
0
1
0
1
+/- 16
0
1
1
0
+/- 24
0
1
1
1
+/- 32
1
1
0
0
+/- 12
1
1
0
1
+/- 20
1
1
1
0
+/- 28
1
1
1
1
+/- 36
1
0
0
0
+/- 40
1
0
0
1
+/- 44
1
0
1
0
+/- 48
1
0
1
1
+/- 52
FCTR[4]: Infrared RX Input Logic Select
• Logic 0 = Select RX input as active high encoded IrDA data, normal, (default).
• Logic 1 = Select RX input as active low encoded IrDA data, inverted.
FCTR[5]: Auto RS485 Enable
Auto RS485 half duplex control enable/disable.
• Logic 0 = Standard ST16C550 mode. Transmitter generates an interrupt when transmit holding register
(THR) becomes empty. Transmit Shift Register (TSR) may still be shifting data bit out.
• Logic 1 = Enable Auto RS485 half duplex direction control. RTS# output changes its logic level from HIGH to
LOW when finished sending the last stop bit of the last character out of the TSR register. It changes from
LOW to HIGH when a data byte is loaded into the THR or transmit FIFO. The change to HIGH occurs prior
sending the start-bit. It also changes the transmitter interrupt from transmit holding to transmit shift register
(TSR) empty.
37