English
Language : 

XR10910 Datasheet, PDF (2/19 Pages) Exar Corporation – 16:1 Sensor Interface
XR10910
Absolute Maximum Ratings
Stresses beyond the limits listed below may cause
permanent damage to the device. Exposure to any Absolute
Maximum Rating condition for extended periods may affect
device reliability and lifetime.
Analog Supply Voltage (VCC).......................................... 0V to 5.5V
Digital Supply Voltage (VDD)........................................... 0V to 5.5V
Digital Input/Output (VDDIO)............................................ 0V to 5.5V
VIN......................................................................................0 to VCC
Differential Input Voltage (current limit of 10mA)....................... VCC
Operating Conditions
Analog Supply Voltage Range................................... 2.7V to 5.25V
Digital Supply Voltage Range.....................................1.7V to 5.25V
Operating Temperature Range..................................-40°C to 85°C
Junction Temperature............................................................ 150°C
Storage Temperature Range....................................-65°C to 150°C
Lead Temperature (Soldering, 10s).......................................260°C
Package Thermal Resistance
θJA (QFN-40)...................................................................... 32°C/W
Package thermal resistance (θJA), JEDEC standard, multi-layer
test boards, still air.
ESD Protection
QFN-40 (HBM)..................................................................... 4000V
HBM - ESD Rating Human Body Model.
© 2014-2015 Exar Corporation
2 / 19
exar.com/XR10910
Rev 1B