R1J-400I1H2A0 Datasheet, PDF (9/12 Pages) List of Unclassifed Manufacturers – 400W+400W Redundant Power Supply | |||
|
◁ |
SURE STAR
SURE STAR
7.3. TTL ä¿¡è TTL signal
POWER SUPPLY CONDITION
NORMAL(POWER SUPPLY ON)
FAILURE(POWER SUPPLY OFF)
OUTPUT CONDITION
Min.
Max.
3V
5.25V
0V
1V
8. è² è¼åæµ Load sharing
輸åºé»å£
è² è¼é»æµ
Output Voltage
Load Current
+12V
1A
è² è¼åæµé»å£
Load Share Voltage
+0.48V ~ +0.52V
9. çµç·£æ§è½ Isolation
9.1. çµç·£é»é» Insulation Resistance
Input To Output 500Vdc , 50M ohms Min.( at room Temperature)
Input To FG 500Vdc , 50M ohms Min.( at room Temperature)
Output To FG Non Insulation
9.2. èå£çµç·£ Dielectric Withstand Voltage
Input To Output 1834Vac (30 mA) for 1 Minute.
Input To FG 1834Vac (30 mA) for 1 Minute.
Output To FG Non Insulation
9.3. ï¥é»é»ï§ Leakage current
å¨120-264 ä¼ç¹/50-60 赫è²æ
æ³ä¸ï¼æ大ï¥é»ï§çº3.5mAã
3.5mA max. at 120~264Vac/50~60HZ.
10. å®å
¨è¦æ± Safety Requirements
-IEC 60950-1
-TUV EN 60950-1
-UL or cUL
-BSMI
-CCC
â¨
|
▷ |