SURE STAR
SURE STAR
4.4. 上升時間 Rise Time
Output Voltage
115/230Vac Input & Full Load
+3.3V
20ms (max.)
+5V
20ms (max.)
+12V
20ms (max.)
-12V
20ms (max.)
+5VSB
20ms (max.)
Note: 上升時間為輸出電壓從10%上升至90%的時間。
The rise time measured is when the output voltages rise from10% to 90% of
specified output voltage Vout observed on the channel waveform.
4.5. 動態響應時間 Dynamic load response time
The following shall apply to the 3.3 V, 5 V, and 12 V outputs:
Output voltage for each output shall recover to within 5 % of its steady state level in less
than 1 ms under the following conditions:
AC Input Voltage: 90VAC ~ 264VAC
Repetition rate of 100Hz with 50 % duty cycle
Output
+3.3V
+5V
+12V
+5SB
Step Load Size
Load Slew Rate
30% to 100% to 30% load
0.5 A/u sec
30% to 100% to 30% load
0.5 A/u sec
60% to 100% to 60% load
1 A/u sec
0% to 100% to 0% load
0.5 A/u sec
Capacitive Load
6000uF
6000uF
6000uf
350uF
4.6. 遠端開關控制 Remote on/off control
The main outputs of this power supply (3.3V,5V,12V,-12V) shall be energized when input
signal*PSON is active. *PSON is an active low TTL compatible signal referenced to the +5V
standby common. This input signal shall be an open collector signal capable of sinking a
minimum of 1.6mA. When *PSON becomes inactive, the main outputs shall be disabled.
PSON Signal
PSU on
LOW (0.8V max)
PSU off
HI (2V max)