English
Language : 

FX-101P-CC2 Datasheet, PDF (8/16 Pages) List of Unclassifed Manufacturers – Digital Fiber Sensor FX-100 SERIES
Digital Fiber Sensor FX-100 SERIES
130
FIBER OPTIONS
Lens (For thru-beam type fiber)
Designation Model No.
Expansion
lens
(Note 1)
FX-LE1
Super-
expansion
lens
(Note 1)
FX-LE2
FIBER
SENSORS
Increases the sensing
range by 5 times or more.
• Ambient temperature:
–60 to +350 °C
–76 to +662 °F
(Note 3)
Tremendously increases the
sensing range with large
diameter lenses.
• Ambient temperature:
–60 to +350 °C
–76 to +662 °F
(Note 3)
The dimensions are on p.120~.
LASER
SENSORS
Description
Sensing range (mm in) [Lens on both sides]
Fiber
FT-B8
Amplifier
FX-101□
2,200 86.614
FX-102□
3,500 137.795 (Note 2)
FT-FM2, FT-T80 3,000 118.110
3,500 137.795 (Note 2)
FT-R80
1,900 74.803
3,500 137.795 (Note 2)
FT-W8
3,000 118.110
3,500 137.795 (Note 2)
FT-P80, FT-P60
3,500 137.795 (Note 2) 3,500 137.795 (Note 2)
FT-P81X
1,600 62.992 (Note 2) 1,600 62.992 (Note 2)
FT-H35-M2
2,000 78.740
3,500 137.795 (Note 2)
FT-H20W-M1
1,300 51.181
1,600 62.992 (Note 2)
FT-H20-M1
1,600 62.992 (Note 2) 1,600 62.992 (Note 2)
FT-H20-J20-S, FT-H20-J30-S, FT-H20-J50-S 1,000 39.370
3,500 137.795 (Note 2)
Sensing range (mm in) [Lens on both sides]
Fiber
Amplifier
FX-101□
FX-102□
FT-B8, FT-FM2, FT-R80, FT-W8, FT-P80, FT-P60 3,500 137.795 (Note 2) 3,500 137.795 (Note 2)
FT-P81X
1,600 62.992 (Note 2) 1,600 62.992 (Note 2)
FT-H35-M2
3,500 137.795 (Note 2) 3,500 137.795 (Note 2)
FT-H20W-M1, FT-H20-M1 1,600 62.992 (Note 2) 1,600 62.992 (Note 2)
FT-H13-FM2
3,500 137.795 (Note 2) 3,500 137.795 (Note 2)
FT-H20-J20-S, FT-H20-J30-S, FT-H20-J50-S 3,500 137.795 (Note 2) 3,500 137.795 (Note 2)
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
SAFETY
COMPONENTS
PRESSURE
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
WIRE-
SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
CONTROL
DEVICES
LASER
MARKERS
Side-view
lens
FX-SV1
Beam axis is bent by 90°.
• Ambient temperature:
–60 to +300 °C
–76 to +572 °F
(Note 3)
Sensing range (mm in) [Lens on both sides]
Fiber
FT-B8
Amplifier
FX-101□
530 20.866
FT-FM2, FT-T80
550 21.654
FT-W8
450 17.717
FT-P80
420 16.535
FT-P60
300 11.811
FT-P81X
550 21.654
FT-H35-M2
280 11.024
FT-H20W-M1
140 5.512
FT-H20-M1
280 11.024
FT-H20-J20-S, FT-H20-J30-S, FT-H20-J50-S
150 5.906
FX-102□
1,450 57.087
1,700 66.929
1,300 51.181
1,400 55.118
850 33.465
1,700 66.929
800 31.496
400 15.748
840 33.071
410 16.142
Expansion
lens for vacuum-
resistant fiber
(Note 1)
FV-LE1
Sensing range increases by Sensing range (mm in) [Lens on both sides] (Note 4)
4 times or more.
• Ambient temperature:
Fiber
Amplifier
FX-101□
FX-102□
–60 to +350 °C –76 to +662 °F FT-H30-M1V
450 17.717
1,600 62.992
(Note 3)
Side-view
lens for
vacuum-
resistant fiber
FV-SV2
Beam axis is bent by 90°.
Sensing range (mm in) [Lens on both sides] (Note 4)
• Ambient temperature:
Fiber
Amplifier
–60 to +300 °C –76 to +572 °F FT-H30-M1V
(Note 3)
FX-101□
450 17.717
FX-102□
1,600 62.992
Notes: 1) Be careful when installing the thru-beam type fiber equipped with the expansion lens, as the beam envelope becomes narrow and alignment is difficult.
Especially when installing a fiber with many cores (sharp bending fibers and heat-resistant glass fiber), please be sure to use it only after you have
adjusted it sufficiently.
2) The fiber cable length practically limits the sensing range to 3,500 mm 137.795 in long (FT-H20W-M1, FT-P81X and FT-H20-M1: 1,600 mm 62.992 in).
3) For details on the ambient temperatures for the fibers which being combined, refer to p.101~.
4) The fiber cable length for the FT-H30-M1V is 1 m 3.281 ft. The sensing ranges in FX-102□ (long sensing range type) take into account the length of the
FT-J8 atmospheric side fiber.
Selection
Guide
Fibers
FT / FD / FR
Fiber Sensor
Amplififiers
FX-100
FX-300
FX-410
FX-311
FX-11A
FX-301-F
Other
Products