Quick setting function
• Settings for “output operation”, “light-emitting amount”,
“timer”, and “emission frequency” are possible simply by
selecting a setting number.
• The quick setting function makes it possible to set
the content of the SET Mode (output operation, timer
operation, amount of light emitted, and frequency of light
emitted) simply by selecting a setting number.
• While in the RUN Mode, pressing and holding both
the ON key ( ) and OFF key ( ) simultaneously for 2
seconds will switch to the quick setting function.
<Table of quick setting numbers>
No. Output operation Emission amount setting
D-ON
OFF
D-ON
ON
D-ON
OFF
D-ON
ON
D-ON
OFF
D-ON
ON
D-ON
OFF
D-ON
ON
D-ON
OFF
D-ON
ON
L-ON
ON
L-ON
OFF
L-ON
ON
L-ON
OFF
L-ON
ON
L-ON
OFF
L-ON
ON
L-ON
OFF
L-ON
ON
L-ON
OFF
Timer
non
non
ofd 10 ms
ofd 10 ms
ofd 40 ms
ofd 40 ms
ond 10 ms
ond 10 ms
ond 40 ms
ond 40 ms
ond 40 ms
ond 40 ms
ond 10 ms
ond 10 ms
ofd 40 ms
ofd 40 ms
ofd 10 ms
ofd 10 ms
non
non
FT / FD / FR
FFiibbeerr Ssensor
AAmmppiliffiiers
FX-100
FX-300
FX-410
FX-311
FX-11A
FX-301-F
Other
Products
Code setting function
• Settings for “output operation”, “timer”, “emission
amount”, “emission frequency”, “ECO”, “external input”,
and “shift amount” are possible by selecting codes
discretionary.
• The code setting function makes it possible to set the
output operation, timer operation, amount of light emitted,
frequency of light emitted, ECO setting, external input,
and amount of shift by selecting a code of one’s choice.
• While in the RUN Mode, pressing and holding both
the ON key ( ) and OFF key ( ) simultaneously for 4
seconds will switch to the code setting function.
<Code table>
1st digit
2nd digit
3rd digit 4th digit
Code
Output
operation
Timer
(Note5)
Emission
amount
setting
Emission
Frequency
FX-101□ FX-102□
ECO
Extemal Shift
input (Note5)
non
0
1
E_oF 5 %
ond 10 ms
1
OFF
D-on ond 40 ms
2
2
Limit [+] 10 %
3 OFF Limit [–] 15 %
ofd 10 ms
3
4
Auto 20 %
ofd 40 ms
0
1
Eco
25 %
non
1
2
ON
ond 10 ms
2
3
E_oF 30 %
Limit [+] 35 %
L-on ond 40 ms
3
4
ON Limit [–] 40 %
ofd 10 ms
Auto 45 %
ofd 40 ms
Eco
50 %
Notes: 1) When the present setting is out of the code setting range, “ ” is
shown.
When “ ” is selected, the set content of the digit is not changed.
2) The factory setting is “
”.
Others
• Do not use during the initial transient time (0.5 sec.) after
the power supply is switched on.
• EEPROM is adopted to this product. It is not possible to
conduct teaching 100 thousand times or more, because
of the EEPROM’s lifetime.