FX-101P-CC2 Datasheet, PDF (6/16 Pages) List of Unclassifed Manufacturers – Digital Fiber Sensor FX-100 SERIES | |||
|
◁ |
Digital Fiber Sensor FX-100 SERIES
128
LIST OF FIBERS
FIBER
SENSORS
Retroreï¬ective type
Fibers are listed in alphabetic order. Refer to p.63~ âFiber Selectionâ for details of each ï¬ber.
Model No.
Sensing range (mm in) (Note 1, 2)
Dimensions
Standard type FX-101â¡ Long sensing range type FX-102â¡
FR-KV1
15 to 200 0.591 to 7.874
15 to 360 0.591 to 14.173
P.112
FR-KZ21
200 7.874
200 7.874
P.112
FR-KZ21E
200 7.874
200 7.874
P.112
FR-WKZ11
100 to 550 3.937 to 21.654
100 to 830 3.937 to 32.677
P.112
Notes: 1) Please take care that the sensing range of the free-cut type ï¬ber may be reduced by 20 % max. depending upon how the ï¬ber is cut.
The sensing range of FR-WKZ11 is speciï¬ed for the RF-13. The sensing range of FR-KZ21, FR-KZ21E and FR-KV1 is speciï¬ed for the attached reï¬ector.
The sensing ranges when using in combination with the FR-WKZ11 reï¬ector (optional) are given in the below table.
Ampliï¬er
Reï¬ector
FX-101â¡
FX-102â¡
FR-WKZ11 + RF-210 100 to 700 3.937 to 27.559 100 to 1,100 3.937 to 43.307
FR-WKZ11 + RF-220 100 to 1,300 3.937 to 51.181 100 to 2,600 3.937 to 102.362
FR-WKZ11 + RF-230 100 to 2,000 3.937 to 78.740 100 to 4,000 3.937 to 157.480
2) The sensing range of FR-WKZ11 is the possible setting range for the reï¬ector or reï¬ective tape. The ï¬ber can detect an object less than 100 mm 3.937 in away.
However, note that if there are any white or highly-reï¬ective surfaces near the ï¬ber head, reï¬ected incident light may affect the ï¬ber head. If this occurs,
adjust the threshold value of the ampliï¬er unit before use.
The sensing range of FR-KZ21(E) is the possible setting range for the reï¬ector. However, if setting the ï¬ber to detect objects passing within 0 to 20 mm
0 to 0.787 in from the ï¬ber head, unstable detection may result.
The sensing range of FR-KV1 is the possible setting range for the reï¬ector. The ï¬ber can detect an object less than 15 mm 0.591 in away.
Reï¬ective type
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
SAFETY
COMPONENTS
PRESSURE
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
WIRE-
SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
CONTROL
DEVICES
LASER
MARKERS
Fibers are listed in alphabetic order. Refer to âFiber Selection p.63~â for details of each ï¬ber.
Model No.
Sensing range (mm in) (Note 1, 2)
Dimensions
Standard type FX-101â¡ Long sensing range type FX-102â¡
Model No.
Sensing range (mm in) (Note 1, 2)
Dimensions
Standard type FX-101â¡ Long sensing range type FX-102â¡
FD-A15
125 4.921
250 9.843 P.113
FD-G6
50 1.969
120 4.724 P.114
FD-AFM2
105 4.134
285 11.220 P.113
FD-G6X
45 1.772
160 6.299 P.114
FD-AFM2E
85 3.346
245 9.646 P.113
FD-H13-FM2
100 3.937
280 11.024 P.114
FD-B8
170 6.693
440 17.323 P.113
FD-H18-L31
0 to 10 0 to 0.394 0 to 25 0 to 0.984 P.115
FD-E12
3.5 0.138
13 0.512 P.113
FD-H20-21
90 3.543
280 11.024 P.115
FD-E22
16 0.630
45 1.772 P.113
FD-H20-M1
120 4.724
300 11.811 P.115
FD-EG1
18 0.709
50 1.969 P.113
FD-H30-KZ1V-S (Note 3) 25 to 80 0.984 to 3.150 10 to 220 0.394 to 8.661 P.115
FD-EG2
10 0.394
30 1.181 P.113
FD-H30-L32
2 to 9 0.079 to 0.354 0 to 17 0 to 0.669 P.115
FD-EG3
7 0.276
22 0.866 P.113
FD-H30-L32V-S (Note 3) 2.5 to 6.5 0.098 to 0.256 0 to 11 0 to 0.433 P.115
FD-EN500S1
1 0.039
4 0.157 P.113
FD-H35-20S
85 3.346
200 7.874 P.116
FD-ENM1S1
FD-F4
FD-F41
15 0.591
48 1.890
Applicable pipe diameter:
Outer dia. ø6 to ø26 mm ø0.236 to
ø1.024 in transparent pipe
[PFA (ï¬uorine resin) or equivalently
transparent pipe, wall thickness 1 mm
0.039 in]
Applicable pipe diameter:
Outer dia. ø6 to ø26 mm ø0.236 to
ø1.024 in transparent pipe
[PVC (vinyl chloride), ï¬uorine resin,
polycarbonate, acrylic, glass, wall
thickness 1 to 3 mm 0.039 to 0.118 in]
P.114
P.114
P.114
FD-H35-M2
FD-H35-M2S6
FD-L4
FD-L41
FD-L43
FD-L44
FD-L44S
FD-L45
75 2.953
280 11.024
5 to 8 0.197 to 0.315 1 to 17 0.039 to 0.669
(Convergent point 6 0.236) (Convergent point 6 0.236)
3 to 14 0.118 to 0.551 1.5 to 16 0.059 to 0.630
(Convergent point 8 0.315) (Convergent point 8 0.315)
0 to 19 0 to 0.748 0 to 25 0 to 0.984
0 to 6 0 to 0.236 0 to 8 0 to 0.315
0 to 4.5 0 to 0.177 0 to 5.5 0 to 0.217
0 to 40 0 to 1.575 0 to 50 0 to 1.969
P.116
P.116
P.116
P.116
P.116
P.116
P.116
P.116
FD-F8Y
â
P.114
FD-L46
16 to 30 0.630 to 1.181 12 to 50 0.472 to 1.969 P.116
FD-FM2
100 3.937
410 16.142 P.114
FD-NFM2
P.117
FD-FM2S
FD-FM2S4
100 3.937
345 13.583
P.114
P.114
FD-NFM2S
FD-NFM2S4
35 1.378
100 3.937
P.117
P.117
FD-G4
50 1.969
120 4.724 P.114
FD-P2
25 0.984
65 2.559 P.117
Notes: 1) The standard sensing objects of the sensing ranges vary depending on the ï¬bers. Refer to p.71~ for details.
2) Please take care that the sensing range of the free-cut type ï¬ber may be reduced by 20 % max. depending upon how the ï¬ber is cut.
3) Sold as a set comprising vacuum-resistant type ï¬ber + photo-terminal (FV-BR1) + ï¬ber at atmospheric side (FT-J8). Please refer to p.91~ for details.
Selection
Guide
Fibers
FT / FD / FR
Fiber Sensor
Ampliï¬fiers
FX-100
FX-300
FX-410
FX-311
FX-11A
FX-301-F
Other
Products
|
▷ |