English
Language : 

FX-101P-CC2 Datasheet, PDF (6/16 Pages) List of Unclassifed Manufacturers – Digital Fiber Sensor FX-100 SERIES
Digital Fiber Sensor FX-100 SERIES
128
LIST OF FIBERS
FIBER
SENSORS
Retroreflective type
Fibers are listed in alphabetic order. Refer to p.63~ “Fiber Selection” for details of each fiber.
Model No.
Sensing range (mm in) (Note 1, 2)
Dimensions
Standard type FX-101□ Long sensing range type FX-102□
FR-KV1
15 to 200 0.591 to 7.874
15 to 360 0.591 to 14.173
P.112
FR-KZ21
200 7.874
200 7.874
P.112
FR-KZ21E
200 7.874
200 7.874
P.112
FR-WKZ11
100 to 550 3.937 to 21.654
100 to 830 3.937 to 32.677
P.112
Notes: 1) Please take care that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
The sensing range of FR-WKZ11 is specified for the RF-13. The sensing range of FR-KZ21, FR-KZ21E and FR-KV1 is specified for the attached reflector.
The sensing ranges when using in combination with the FR-WKZ11 reflector (optional) are given in the below table.
Amplifier
Reflector
FX-101□
FX-102□
FR-WKZ11 + RF-210 100 to 700 3.937 to 27.559 100 to 1,100 3.937 to 43.307
FR-WKZ11 + RF-220 100 to 1,300 3.937 to 51.181 100 to 2,600 3.937 to 102.362
FR-WKZ11 + RF-230 100 to 2,000 3.937 to 78.740 100 to 4,000 3.937 to 157.480
2) The sensing range of FR-WKZ11 is the possible setting range for the reflector or reflective tape. The fiber can detect an object less than 100 mm 3.937 in away.
However, note that if there are any white or highly-reflective surfaces near the fiber head, reflected incident light may affect the fiber head. If this occurs,
adjust the threshold value of the amplifier unit before use.
The sensing range of FR-KZ21(E) is the possible setting range for the reflector. However, if setting the fiber to detect objects passing within 0 to 20 mm
0 to 0.787 in from the fiber head, unstable detection may result.
The sensing range of FR-KV1 is the possible setting range for the reflector. The fiber can detect an object less than 15 mm 0.591 in away.
Reflective type
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
SAFETY
COMPONENTS
PRESSURE
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
WIRE-
SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
CONTROL
DEVICES
LASER
MARKERS
Fibers are listed in alphabetic order. Refer to “Fiber Selection p.63~” for details of each fiber.
Model No.
Sensing range (mm in) (Note 1, 2)
Dimensions
Standard type FX-101□ Long sensing range type FX-102□
Model No.
Sensing range (mm in) (Note 1, 2)
Dimensions
Standard type FX-101□ Long sensing range type FX-102□
FD-A15
125 4.921
250 9.843 P.113
FD-G6
50 1.969
120 4.724 P.114
FD-AFM2
105 4.134
285 11.220 P.113
FD-G6X
45 1.772
160 6.299 P.114
FD-AFM2E
85 3.346
245 9.646 P.113
FD-H13-FM2
100 3.937
280 11.024 P.114
FD-B8
170 6.693
440 17.323 P.113
FD-H18-L31
0 to 10 0 to 0.394 0 to 25 0 to 0.984 P.115
FD-E12
3.5 0.138
13 0.512 P.113
FD-H20-21
90 3.543
280 11.024 P.115
FD-E22
16 0.630
45 1.772 P.113
FD-H20-M1
120 4.724
300 11.811 P.115
FD-EG1
18 0.709
50 1.969 P.113
FD-H30-KZ1V-S (Note 3) 25 to 80 0.984 to 3.150 10 to 220 0.394 to 8.661 P.115
FD-EG2
10 0.394
30 1.181 P.113
FD-H30-L32
2 to 9 0.079 to 0.354 0 to 17 0 to 0.669 P.115
FD-EG3
7 0.276
22 0.866 P.113
FD-H30-L32V-S (Note 3) 2.5 to 6.5 0.098 to 0.256 0 to 11 0 to 0.433 P.115
FD-EN500S1
1 0.039
4 0.157 P.113
FD-H35-20S
85 3.346
200 7.874 P.116
FD-ENM1S1
FD-F4
FD-F41
15 0.591
48 1.890
Applicable pipe diameter:
Outer dia. ø6 to ø26 mm ø0.236 to
ø1.024 in transparent pipe
[PFA (fluorine resin) or equivalently
transparent pipe, wall thickness 1 mm
0.039 in]
Applicable pipe diameter:
Outer dia. ø6 to ø26 mm ø0.236 to
ø1.024 in transparent pipe
[PVC (vinyl chloride), fluorine resin,
polycarbonate, acrylic, glass, wall
thickness 1 to 3 mm 0.039 to 0.118 in]
P.114
P.114
P.114
FD-H35-M2
FD-H35-M2S6
FD-L4
FD-L41
FD-L43
FD-L44
FD-L44S
FD-L45
75 2.953
280 11.024
5 to 8 0.197 to 0.315 1 to 17 0.039 to 0.669
(Convergent point 6 0.236) (Convergent point 6 0.236)
3 to 14 0.118 to 0.551 1.5 to 16 0.059 to 0.630
(Convergent point 8 0.315) (Convergent point 8 0.315)
0 to 19 0 to 0.748 0 to 25 0 to 0.984
0 to 6 0 to 0.236 0 to 8 0 to 0.315
0 to 4.5 0 to 0.177 0 to 5.5 0 to 0.217
0 to 40 0 to 1.575 0 to 50 0 to 1.969
P.116
P.116
P.116
P.116
P.116
P.116
P.116
P.116
FD-F8Y
–
P.114
FD-L46
16 to 30 0.630 to 1.181 12 to 50 0.472 to 1.969 P.116
FD-FM2
100 3.937
410 16.142 P.114
FD-NFM2
P.117
FD-FM2S
FD-FM2S4
100 3.937
345 13.583
P.114
P.114
FD-NFM2S
FD-NFM2S4
35 1.378
100 3.937
P.117
P.117
FD-G4
50 1.969
120 4.724 P.114
FD-P2
25 0.984
65 2.559 P.117
Notes: 1) The standard sensing objects of the sensing ranges vary depending on the fibers. Refer to p.71~ for details.
2) Please take care that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
3) Sold as a set comprising vacuum-resistant type fiber + photo-terminal (FV-BR1) + fiber at atmospheric side (FT-J8). Please refer to p.91~ for details.
Selection
Guide
Fibers
FT / FD / FR
Fiber Sensor
Amplififiers
FX-100
FX-300
FX-410
FX-311
FX-11A
FX-301-F
Other
Products