English
Language : 

CME6005 Datasheet, PDF (7/16 Pages) List of Unclassifed Manufacturers – Single and dual band receiver IC
Preliminary Data Sheet CME6005 C-MAX
8 Electrical Characteristics
V
CC
=
3V,
input
signal
frequency
77.5
kHz
+/-
5
Hz;
carrier
voltage
100%
reduction
to
25%
for
tMOD
=
200ms;
tamb = 25°C, max./min. limits are at +25...C ambient temperature, unless otherwise specified.
Parameter
Supply voltage range
Supply current
Set-up time after VCC ON
Reception frequency range
Minimum input voltage
Maximum input voltage
Input amplifier max. gain
(VPK = 0.2V)
Input amplifier min. gain
(VPK = 0.8V)
Pins TCO, TCON
Output low
Output high
Test condition / Pin
Pad/Pin VCC
Pad/Pin VCC
VCC = 3V
Pad/Pin IN1, IN2
Pad/Pin IN1, IN2
Symbol
VCC
ICC
t
Fin
Vin
Vin
VU1
VU2
Min.
1.2
40
30
Typ.
<90
1.5
0.4
50
47
-40
Max.
5.5
100
120
0.6
Unit
V
µA
s
kHz
µV
mV
dB
dB
lol = 10µA
loh = -10µA
0.9 x Vcc
0.1 x VCC
V
V
Power-ON control; PON Pad/Pin PON
Input level
Input leakage current
Low level
High level
0<Vi < Vcc
0.85 Vcc
-0.1
0.15 Vcc V
V
0.1 µA
Quiescent current receiver OFF VPON=VCC, Pad/Pin VCC
ICC0
Set-up time after PON
t
AGC hold mode; HLD
Pad/Pin HLD
0.03 0.05 µA
0.5
2
s
Input level
Input leakage current
Low level
High level
0<Vi < Vcc
0.85 Vcc
-0.1
0.15 Vcc V
V
0.1 µA
AC characteristics
Output pulse width for TCO and Modulation according
TCON
DCF, 200 ms pulse
tWO200
170
Output pulse width for TCO and Modulation according
TCON
DCF, 100 ms pulse
tWO100
70
195
230 ms
95
130 ms
SPEC No.
CME6005
Revision
A.7
State
07.12.04
C-MAX printed
07.12.2004
Version
English
Page
7 of 16