English
Language : 

C5001 Datasheet, PDF (7/13 Pages) List of Unclassifed Manufacturers – Low Skew Multiple Frequency PCI Clock Generator with EMI Reducing SSCG.
C5001
Low Skew Multiple Frequency PCI Clock Generator with EMI Reducing SSCG.
Approved Product
2-Wire I2C Control Interface
The 2-wire control interface implements write block mode write only slave interface. Sub addressing is not supported,
thus all preceding bytes must be sent in order to read or change one of the control bytes. The 2-wire control interface
allows each clock output to be individually controlled.
During normal data transfer, the SDATA signal only changes when the SDCLK signal is low, and is stable when SDCLK
is high. There are two exceptions to this. A high to low transition on SDATA while SDCLK is high is used to indicate the
start of a data transfer cycle. A low to high transition on SDATA while SDCLK is high indicates the end of a data transfer
cycle. Data is always sent as complete 8-bit bytes, after which an acknowledge is generated. The first byte of a transfer
cycle is a 7-bit address with a Read/Write bit as the LSB (bit 0). Data is transferred MSB (bit 7) first.
The device will respond to writes up to 6 bytes (max) of data to address D2. The device will not respond to any other
control interface conditions.
Serial Control Registers
NOTE: The Pin# column lists the affected pin number where applicable. The @Pup column gives the state at true
power up. Bytes are set to the values shown only on true power up.
Following the acknowledge of the Address Byte (D2), two additional bytes must be sent:
1) “Command Code “ byte, and
2) “Byte Count” byte.
Although the data (bits) in these two bytes are considered “don’t care”; they must be sent and will be acknowledged.
After the Command Code and the Count bytes have been acknowledged, the described sequence below (Byte 0, Byte 1,
Byte2,) will be valid and acknowledged.
Byte 0: Function Select Register (1 = enable, 0 = Stopped)
Bit
@Pup Pin# Description
7
1
14 CLK7 (Active = 1, Forced low = 0)
6
1
15 CLK6 (Active = 1, Forced low = 0)
5
1
18 CLK5 (Active = 1, Forced low = 0)
4
1
19 CLK4 (Active = 1, Forced low = 0)
3
1
22 CLK3 (Active = 1, Forced low = 0)
2
1
23 CLK2 (Active = 1, Forced low = 0)
1
1
26 CLK1 (Active = 1, Forced low = 0)
0
1
27 CLK0 (Active = 1, Forced low = 0)
INTERNATIONAL MICROCIRCUITS, INC. 525 LOS COCHES ST.
MILPITAS, CA 95035. TEL: 408-263-6300. FAX 408-263-6571
Rev.2.1
6/14/1999
Page 7 of 13