English
Language : 

MLX90609 Datasheet, PDF (6/22 Pages) List of Unclassifed Manufacturers – Angular Rate Sensor (Standard version)
MLX90609
Angular Rate Sensor (Standard version)
4. MLX90609 Sensor Specific Specifications
DC Operating Parameters TA = -40°C to 85°C, VDD = 4.75V to 5.25V (unless otherwise specified)
Parameter
Symbol
Test Conditions Min Typ Max Units
Output Full Scale
(on OUTAR pin)
Full Scale Range
Linearity Note 2
Initial Scale Factor (sensitivity)
FS OUT = U OUT ,Ω max
− U OUT ,Ω min
Factory set for N2 version
FSin
Factory set for E2 version
Factory set for R2 version
S0
=
FSOUT
FSIN
Output, best fit based
Data are given for
N2, E2 and R2 versions
respectively and
according to the Full
Scale Range Setting.
At 25°C, VDD=5V.
Scale Factor drift (sensitivity drift) Note 1
-40..+85ºC temperature
range, supply voltage
-5
variation included
4
V
1920
LSB
±75
±150
°/s
±300
+/- 0.5 % FSOUT
26.67
13.33
6.67
12.8
6.4
3.2
mV/°/sec
LSB/°/sec
5
%S0
Zero Rate Output (Bias)
Zero Rate Temperature drift
(Bias drift) Note 1
Zero Rate Supply Drift
2.5
V
ZRO
at 25ºC, VDD=5V
1008
LSB
-40...+85ºC temperature
range, VDD=5V
-5
0
5
% FSOUT
250
mV/V
4.75..5.25V at 25°C
120
LSB/V
Bandwidth (-3 dB) Note 2
FLT to OUTAR capacitor value Note 2
Output Noise power spectral density
Angular Rate Cross-sensitivity
for 0x,0y Note 2
Selectable by external
capacitor (section 7)
7 Hz Bandwidth
(-4.5 to -1 dB)
At 250C
for a full-scale angular
rate along 0x,0y
75
Hz
100
±5%
nF
0.03
°/sec/√Hz
1
2
%FSOUT
390109060901
Rev 007
Page 6 of 22
Data Sheet
January/08