English
Language : 

MLX90609 Datasheet, PDF (5/22 Pages) List of Unclassifed Manufacturers – Angular Rate Sensor (Standard version)
MLX90609
Angular Rate Sensor (Standard version)
3. MLX90609 General Electrical Specifications
DC Operating Parameters TA = -40°C to 85°C, VDD = 4.75V to 5.25V.
Parameter.
Supply Voltage
Symbol
VDD
Test Conditions
Min Typ Max Units
4.75
5.25
V
Supply Current
IDD
No output load
16
20
mA
Output capacitive load to VDD or VSS
Analog output
0
100
pF
Output resistive load
Output, max
Output, min
Voltage Reference load current Note 3
Logic Input, Low Voltage
Logic Input, High Voltage
Clock Input, Low Voltage
Clock Input, High Voltage
Clock Input, Hysteresis Voltage
Logic Output, Low Voltage
Logic Output, High Voltage
Input high current with pull-up
Input low current with pull-up
Input high current with pull-down
Input low current with pull-down
Tri-State Output Leakage current
Analog output
200k
∞
Ohm
U OUT ,Ω max
U OUT ,Ωmin
IREF
Analog output
Analog output
Analog output
4.5
V
0.5
V
-10
10
µA
VIL
SS , MOSI
0
0.3 x VDD V
VIH
SS , MOSI
0.7 x VDD
VDD
V
VILC
SCLK
0
0.8
V
VIHC
SCLK
2.8
VDD
V
VHC
SCLK
1.1
V
VOL
MISO, ERROR, IO < 8 mA
0
0.4
V
VOH
MISO, ERROR, IO < 8 mA
2.4
VDD
V
IIH_UP
SS , SCLK, VIN = VDD
-10
IIL_UP
SS , SCLK, VIN = VSS
-10
IIH_DOWN
MOSI, VIN = VDD
200
10
µA
-200
µA
10
µA
IIL_DOWN
MOSI, VIN = VSS
-10
10
µA
IOZ
MISO
-10
10
µA
Table 3. DC Electrical Characteristics
390109060901
Rev 007
Page 5 of 22
Data Sheet
January/08