English
Language : 

IL-P3 Datasheet, PDF (6/14 Pages) List of Unclassifed Manufacturers – Image Sensors
IL-P3
Line Scan Sensors
For product information and updates visit www.dalsa.com
Table 7. IL-P3 AC Operating Conditions
Symbol Description
Unit
Min.

Rec.
Max.
CRx
All CR Clocks
low*
V
0
RST2
Reset Clock
swing*
V
4.8
5.0
6.5
low
V
0
swing
V
7.0
7.0
9.0
TCK
Transfer Clock
low
V
-5.0
-3.5
-3.5
high
V
4.5
5.0
6.0
PR
Pixel Reset Clock
low
V
0
ƒDATA3
ƒLINE4
Data rate
Line rate
swing
V
3.5
MHz
5
0512
kHz
1024
4.0
6.0
45
82.3
42.5
2048
21.6
Notes:
1. When deviating from the recommended biases, ensure that the new biases still meet the essential conditions on
Table 8.
2. If it is important that RST have a 5-V swing, an alternate set of biases is available. Contact DALSA for additional
information. The alternative biases result in a reduction of either the antiblooming performance or VSAT.
3. The minimum data rate can be lower than 5MHz if 100x antiblooming is not required.
4. Unless the pixel is reset using the PR clock, the integration time increases as line rate decreases. Dark signal is
proportional to the integration time. The minimum line rate is determined by the maximum dark signal or the
maximum dark signal shot noise that the application can tolerate.
*
Table 8. IL-P3 Essential Bias Conditions
Conditions
If condition not satisfied, the sensor will exhibit…
CR1 high + 1 > TCK > VSTOR + 3
PR high > VSTOR + 1.5
RST high + 5.5 > VOD
VOD < VDD - 1.5
VLOW > VBB + 2
Larger lag
High PRNU when exposure control is enabled
Poor MTF
Higher non-linearity
Spurious charge injection under certain power-up
conditions
$
ISO 9001
DALSA INC.: Phone: 519-886-6000 Fax: 519-886-8023
DALSA EUROPE: Phone: +49-8142-46770 Fax: +49-8142-467746
03-36-00166-06