INITIALISATION EXAMPLE
Command
(6) Set Scroll Line
(13) Set SEG direction
(14) Set COM direction
(10) Set All Pixel On
(11) Set Inverse Display
(17) Set LCD Bias Ratio
(5) Set Power Control
(8) Set VLCD Resistor Ratio
(9) Set Electronic Volume
(25) Set Adv. Program Control 0
(12) Set Display Enable
Initialisation example (bottom view)
CD D7 D6 D5 D4 D3 D2 D1 D0 Hex Remark
0 0 1 0 0 0 0 0 0 $40 Display start line 0
0 1 0 1 0 0 0 0 1 $A1 SEG reverse *)
0 1 1 0 0 0 0 0 0 $C0 Normal COM0~COM63
0 1 0 1 0 0 1 0 0 $A4 Disable -> Set All Pixel to ON
0 1 0 1 0 0 1 1 0 $A6 Display inverse off
0 1 0 1 0 0 0 1 0 $A2 Set Bias 1/9 (Duty 1/65)
0 0 0 1 0 1 1 1 1 $2F Booster, Regulator and Follower on
0 0 0 1 0 0 1 1 1 $27
1 0 0 0 0 0 0 1 $81 Set Contrast
0
0 0 0 1 0 0 0 0 $10
0 1 1 1 1 1 0 1 0 $FA Set Temperature compensation
1 0 0 1 0 0 0 0 $90 curve to -0.11%/°C
0 1 0 1 0 1 1 1 1 $AF Display on
*) Make sure that for 6:00 viewing direction SEG has to be set to „reverse“ (mirrored layout) !
12:00 VIEWING ANGLE, TOP VIEW OPTION
If the display is read mostly from above (on the front of a laboratory power supply unit, for example), the preferred
angle of viewing can be set to 12 o’clock.This rotaties the display by 180°.Aslightly different initialization setup is
required for this.Also keep in mind that the leftmost column (normally numbered as 0) will now change to 30.
Command
(13) Set SEG direction
(14) Set COM direction
Initialisation example (changes for top view)
CD D7 D6 D5 D4 D3 D2 D1 D0 Hex Remark
0 1 0 1 0 0 0 0 0 $A0 SEG normal
0 1 1 0 0 1 0 0 0 $C8 COM reverse COM63~COM0
Orientation for 6 o’clock
(Bottom View)
Orientation for 12 o’clock
(Top View)