English
Language : 

BXRA-56C0700 Datasheet, PDF (6/24 Pages) List of Unclassifed Manufacturers – Bridgelux ES Star Array Series
Selection Guide
The following configurations are available:
Table 1: Selection Guide for ES Star Arrays
Part Number [1]
CCT [2]
(Kelvin)
CRI
[3,4]
Test
Typical
Current [5] Voltage
(mA)
(V)
BXRA-27E0540-A-03 2700
80
350
18.2
BXRA-27E0740-A-03 2700
80
350
27.3
BXRA-27G0540-A-03 2700
90
350
18.2
BXRA-27G0740-A-03 2700
90
350
27.3
BXRA-30E0540-A-03 3000
80
350
18.2
BXRA-30E0740-A-03 3000
80
350
27.3
BXRA-30G0540-A-03 3000
90
350
18.2
BXRA-30G0740-A-03 3000
90
350
27.3
BXRA-40E0600-A-03 4000
80
350
18.2
BXRA-40E0810-A-03 4000
80
350
27.3
BXRA-50C1000-A-xx 5000
70
350
27.3
BXRA-56C0700-A-xx 5600
70
350
18.2
BXRA-56C1000-A-xx 5600
70
350
27.3
Typical Flux [6] (lm)
Tj = 25ºC
580
850
480
720
630
920
530
780
680
1030
1150
790
1150
Tcase = 85ºC
505
740
415
625
550
800
460
680
590
895
1000
685
1000
Typical
Power[4]
(W)
6.4
9.6
6.4
9.6
6.4
9.6
6.4
9.6
6.4
9.6
9.6
6.4
9.6
Typical
Efficacy[4]
(lm/W)
91
89
75
75
99
96
83
82
107
108
120
124
120
Note for Table 1 through 5 (additional specific notes following Table 2 through 5):
1. Part numbers with “-xx” suffix are available with multiple color control options (4 SDCM or 7
SDCM for example).
2. Nominal CCT as defined by ANSI C78.377-2011.
3. Values are mimimum.
4. Minimum R9 value for 90 CRI products is 50.
5. Products tested under pulsed condition (10ms pulse width) at rated test current where Tjunction =
Tcase = 25°C.
6. Typical performance values are provided as a reference only and are not a guarantee of
performance.
7. Bridgelux maintains a ±7% tolerance on flux measurements.
8. Operating these LED Arrays at or below the drive currents listed in Table 2 and 5, with a case
temperature maintained at or below 85°C, will enable the average lumen maintenance projection
outlined earlier in this Product Data Sheet.
Bridgelux ES Star Array Series Product Data Sheet DS23 (8/30/2013 rev2)
Page 6 of 24