KXCNL-1010 Datasheet, PDF (49/51 Pages) List of Unclassifed Manufacturers – Accelerometer Specifications
± 2g / 4g / 6g / 8g Tri-axis Digital
Accelerometer Specifications
PART NUMBER:
KXCNL-1010
Rev 3.0
State Program OP Codes
# Mnemonic Explanation
Notes
0h
NOP
No operation
1h
TI1
Timer 1 valid
Execution moved to next or
resetconditions in state
Data samples are not evaluated
2h
TI2
Timer 2 valid
Data samples are not evaluated
3h
TI3
Timer 3 valid
Data samples are not evaluated
4h
TI4
Timer 4 valid
Data samples are not evaluated
5h
GNTH1
Any/triggered axis greater than threshold 1
First axis triggers
6h
GNTH2
Any/triggered axis greater than threshold 2
First axis triggers
7h
LNTH1
Any/triggered axis less than or equal to threshold 1
First axis triggers
8h
LNTH2
Any/triggered axis less than or equal to threshold 2
First axis triggers
9h
GTTH1
Any/triggered axis greater than threshold 1
First axis triggers
Ah
LLTH2
All axis less than or equal to threshold 2
First masked axis triggers
Bh
GRTH1
Any/triggered axis greater than to reversed threshold 1 First axis triggers
Ch
LRTH1
Any/triggered axis less than or equal to reversed
threshold 1
First axis triggers
Dh
GRTH2
Any/triggered axis greater than to reversed threshold 2 First axis triggers
Eh
LRTH2
Any/triggered axis less than or equal to reversed
threshold 2
Fh
NZERO
Any axis zero crossed
First axis triggers
Uses previous data samples sign
First axis triggers
Table 1. Conditions
#
Mnemonic Explanation
00h
STOP
Stop execution, and resets reset-point to
start
11h
CONT
Continues execution from reset-point
Jump address for two Next conditions
22h
JMP
- 1st parameter is conditions
- 2nd parameter are addresses for valid
conditions
33h
SRP
Set reset-point to next address / state
44h
CRP
Clear reset-point to start position (to 1st
address)
Set parameter in register memory
55h
SETP
-1st is address of parameter
- 2nd parameter is new parameter set to
address
66h
SETS1
Set new setting to Settings 1 register
- 1st is new settings byte
77h
STHR1
Set new value to /THRS1_y register
- 1st is new settings byte
88h
OUTC
Set outputs to output registers
Run Scope
Immediately
Immediately
Notes
Output also if enabled
Output also if enabled
Immediately for command Special (command and
& Sample for conditions conditions)
Immediately
Immediately
Immediately
Immediately
Immediately
Immediately output
Address parameter is direct
absolute pointer to register
memory
36 Thornwood Dr. – Ithaca, NY 14850
tel: 607-257-1080 – fax:607-257-1146
www.kionix.com - info@kionix.com
© 2013 Kionix – All Rights Reserved
1.0