KXCNL-1010 Datasheet, PDF (46/51 Pages) List of Unclassifed Manufacturers – Accelerometer Specifications
± 2g / 4g / 6g / 8g Tri-axis Digital
Accelerometer Specifications
PART NUMBER:
KXCNL-1010
Rev 3.0
/SETT2
The register that controls the State Program 2 flow.
-/W
P_DET
Bit7
-/W
THR3_SA
Bit6
-/W
ABS
Bit5
-/W
RADI
Bit4
-/W
D_CS
Bit3
-/W
-/W
-/W
THR3_MA R_TAM SITR
Bit2
Bit1
Bit0
I2C Address: 0x7Bh
P_DET is the peak detection control bit.
P_DET = 0 peak detection disabled.
P_DET = 1 peak detection enabled in State Program 2.
THR3_SA controls the reset action when Threshold 3 is exceeded and mask is /SA2.
THR3_SA = 0 no action.
THR3_SA = 1 Exceeding Threshold 3 immediately triggers Reset action if mask is
/SA2 (/MASA2 == 1). Every sample and every axis is tested to determine if it
exceeds Threshold 3 regardless of the /TAMxA2 value. /THRS3 (register) limit is
common for both State Programs.
ABS is the peak absolute threshold enable/disable control.
ABS = 0 unsigned thresholds. Thresholds are symmetric across the zero line.
ABS = 1 signed thresholds in State Program 2. Thresholds are sign dependent.
RADI controls difference data mode. Only for State Program 2.
RADI = 0 use raw data
RADI = 1 use difference data in State Program 2.
D_CS DIFF2 or constant shift mode. Only for State Program 2.
D_CS = 0 DIFF2
D_CS = 1 constant shift for DIFF definition
THR3_MA controls the reset action when Threshold 3 is exceeded and mask is /MA2.
THR3_MA = 0 no action.
THR3_MA = 1 Exceeding Threshold 3 immediately triggers Reset action if mask is
/SA2 (/MASA2 == 0). Every sample and every axis is tested to determine if it
exceeds Threshold 3 regardless of the /TAMxA2 value. /THRS3 (register) limit is
common for both State Programs.
R_TAM is the temporary axis mask and peak state flag release.
R_TAM = 0 no changes for /TAMxA2.
R_TAM = 1 /TAMxA2 released to default after every valid NEXT condition.
SITR is the temporary axis mask and peak state flag release.
SITR = 0 no actions.
SITR = 1 STOP and CONT commands proceeds also output as OUTC command.
36 Thornwood Dr. – Ithaca, NY 14850
tel: 607-257-1080 – fax:607-257-1146
www.kionix.com - info@kionix.com
© 2013 Kionix – All Rights Reserved
1.0
Page 46 of 51