SP12N002 Datasheet, PDF (4/23 Pages) – | |||
|
◁ |
4. ABSOLUTE MAXIMUM RATINGS
4.1 ELECTRICAL ABSOLUTE MAXIMUM RATINGS
ITEM
SYMBOL MIN. MAX.
Power Supply for Logic
VDD-VSS 0
6.5
Power Supply for LC Drive
VDD-VEE 0
20.5
Input Voltage
VI
-0.3 VDD+0.3
Input Current
Ii
0
1
Static Electricity
-
-
-
Note 1: Make certain you are grounded when handling LCM
UNIT
V
V
V
A
-
COMMENT
Note1
4.2 ENVIRONMENTAL ABSOLUTE MAXIMUM RATINGS
ITEM
OPERATING
MIN. MAX.
STORAGE
MIN. MAX.
Ambient Temperature
0â
50â -20â
60â
Humidity
Note1
Note1
Vibration
-
4.9m/s2
(0.5G)
-
19.6m/s2
(2G)
Shock
-
29.4m/s2
(3G)
-
490.0m/s2
(50G)
Corrosive Gas
Not acceptable Not acceptable
COMMENT
Note2,3
Without Condensation
Note4
XYZ Direction
Note 1: Taâ¦40â : 85%RH max.
Taï¼40â : Absolute humidity must be lower
Than the humidity of 85%Rh at 40â.
Note 2: Ta at -20âï¼48h, At 60â-----ï¼168h
Note 3: Background color changes slightly depending on ambient temperature.
This phenomenon is reversible. Higher starting voltage of CFL and higher
LCD driving voltage are needed while operating at 0â. The life time of CFL
will be reduced while operating at 0â need to make sure of value of IL and
characteristics of inverter. Also the response time at 0â will be slower.
Note 4: 5Hz~100Hz (Except resonance frequency)
Note 5: This module should be operated normally after finish the test.
KAOHSIUNG OPTO-ELECTRONICS INC.
SHEET
NO.
7B64PS 2704-SP12N002-5
PAGE 4-1/1
|
▷ |