11.3 CAUTION AGAINST STATIC CHANGE
As this module is provided with C-MOS LSIs, the care to take such a precaution
as to grounding the operator’s body is required when handling it.
11.4 POWER ON SEQUENCE
Input signals should not be applied to LCD module before power supply voltage
is applied and reaches to specified voltage (5 ±0.25V). If above sequence is not
kept, C-MOS LSIs of LCD modules may be damaged due to latch up problem.
11.5 PACKAGING
(1) No. Leaving products is preferable in the place of storage in the place where
high humidity for a long period of time. For their temperature is 35℃ or higher,
special care to prevent them from high humidity is required. A combination of
high temperature and high humidity may cause them polarization degradation
as well as bubble generation and polarizer peel-off.
Please keep the temperature and humidity within the specified range for use and
storing.
(2) Since upper polarizers and lower aluminum plates tend to be easily damaged,
they should be handled with full care so as not to get them touched, pushed
or rubbed by a piece of glass. Tweezers and anything else which are harder
than a pencil lead 3H.
(3) As the adhesives used for adhering upper/lower polarizers and aluminum plates
are made of organic substances which will be deteriorated by a chemical reaction
with such chemicals as acetone, Toulon ethanol and isopropylalcohol.
The following solvents are recommended for use:
NORMAL HEXANE
Please contact with us when it is necessary for you to use chemicals other
than the above.
(4) Lightly wipe to clean the dirty surface with absorbent cotton waste or other soft
material like chamois, soaked in the chemicals recommended without scrubbing
it hardly. To prevent the display surface from damage and keep the appearance
in good state, it is sufficient, in general, to wipe it with absorbent cotton.
(5) Immediately wipe off saliva or water drop attached on the display area because
its long period adherence may cause deformation or faded color on the spot.
(6) Fogy dew deposited on the surface and contact terminals due to godliness will
be a cause for polarizer damage, stain and dirt on product. When necessary to
take out the products from some place at low temperature for test, etc. It is
required for them to be warmed up in a container once at the temperature higher
than that of room.
(7) Touching the display area and contact terminals with bare hands and contaminating
them are prohibited, because the stain on the display area and poor insulation
between terminals are often caused by being touched by bare hands.
(There are some cosmetics detrimental to polarizers.)
(8) In general the quality of glass is fragile so that it tends to be cracked or chipped
in handling, specially on its periphery. Please be careful not to give it sharp shock
caused by dripping down, etc.