SECTION 6 — ACCIDENTAL RELEASE MEASURES
Personal Precautions:
Environmental Precautions:
Steps to be taken in case of spill:
Waste Disposal Method:
Other Precautions:
Wearing protective clothing, eye protection, and inhalation
protection.
Keep spills and cleaning runoffs out of municipal sewers and open
bodies of water.
Soak up with sawdust, sand, or other absorbent material. Shovel
or sweep up. Flush spill area with water.
Discard material according to local, state, and federal regulations.
Mop up spills immediately. Wet floors may present slip hazard.
SECTION 7 — HANDLING AND STORAGE
Handling:
Use in well-ventilated areas; avoid breathing vapors.
Keep containers closed when not in use. Avoid from
freezing. For commercial and industrial use only.
Storage:
Storage temperature: Max. 49°C/120°F 1°C/34°F.
Keep from freezing.
SECTION 8 — EXPOSURE CONTROL / PERSONAL PROTECTION
Ingredients:
Ethylene Glycol Monobutyl Ether
CAS No.
111-76-2
TLV-value
25 ppm
Control Parameters:
Respiratory Protection
Ventilation
Protective Gloves
Eye protection
Other Protective Equipment
Work/Hygienic Practices
TLV-valve 25 ppm maximum for Ethylene Glycol Monobutyl
Wear MSHA/NIOSH approved respirator where exposure limits are
exceeded
Provide general clean air dilution or local exhaust ventilation in
volume and pattern to prevent air con-taminant concentration
build-up.
If there is potential for prolonged or repeated skin contact, wear
plastic gloves for the duration of anticipated exposure.
Avoid contact with eyes. Use safety eyewear with splash guards or
side shields.
None normally required. If unable to avoid prolonged or repeated
contact with skin, wear protective clothing.
Wash hands before eating, smoking, or using washroom facilities
SECTION 9 — PHYSICAL AND CHEMICAL PROPERTIES
Physical State:
Color:
Smell:
pH:
Boiling Point:
Melting Point:
Flash Point:
Flammability Limits:
Solubility in Water:
Vapor Pressure (mm Hg):
Vapor Density (air=1):
Specific Gravity (H2O = 1):
Density at 20°C:
Ignition Temperature:
VOC per Method 24 of EPA:
Liquid
Clear
N/A
6.5-7.5
>200°F (94°C)
N/A
Noncombustible
N/A
Complete
18.0
<1.0
1.0 - 1.2
8.17 lbs./gal
N/A
6% VOC by wt.
*This product meets VOC requirements per Title 17, California Code of Regulations, Division 3 Chapter 1,
Subchapter 8.5, Article 2, Section 94509
SECTION 10 — STABILITY AND REACTIVITY
Stability/Reactivity
Conditions to avoid
Materials to avoid
Hazardous Decomposition
Stable product at normal conditions
Temperatures above 49°C/120°F and below 1°C/34°F
Avoid contamination with strong acids and oxidizing agents
Thermal decomposition may yield carbon monoxide.
DESCO INDUSTRIES INC. • 3651 Walnut Avenue, Chino, CA 91710 • (909) 627-8178 • Web Site: DescoIndustries.com
TB-7005 Page 4 of 6
© 2012 DESCO INDUSTRIES, INC.
Employee Owned