English
Language : 

M10478 Datasheet, PDF (27/30 Pages) List of Unclassifed Manufacturers – GPS RADIONOVA® RF Antenna Module
®
m2m
GPS RADIONOVA® RF Antenna Module
Part No. M10478
Quality and Environmental Specifications
Test
Standard
Parameters
PCB Inspection
IPC-6012B, Class 2. Qualification and
Performance Specification for Rigid Printed
Boards - Jan 2007
Assembly
Inspection
IPC-A-610-D, Class 2 “Acceptability of
electronic assemblies”
Temperature
Range
ETSI EN 300 019-2-7 specification T 7.3
-30 °C, +25 °C, +85 °C, operating
Damp Heat
ETSI EN 300 019-2-7 specification T 7.3
+70 °C, 80% RH, 96 hrs, non-
operating
Thermal Shock
ETSI EN 300 019-2-7 specification T 7.3 E -40 °C ... +85 °C, 200 cycles
Vibration
ISO16750-3
Random vibration, 10~1000Hz,
27.8m/s2, 8hrs/axis, X, Y, Z 8hrs for
each 3 axis non-operating
Shock
ISO16750-3
Half-sinusoidal 50g, 6ms, 10time/face,
±X, ±Y and ±Z non-operating
Free Fall
ISO16750-3
1m height, 2 drops on opposite side
ESD Sensitivity
JEDEC, JESD22-A114 ESD Sensitivity
+2000V - Human hand assembly
Testing Human Body Model (HBM). Class 2
JEDEC, JESD22-A115 ESD Sensitivity
Testing Machine Model (MM), Class B
+200V - Machine automatic final
assembly
Shear
IEC 60068-2-21, Test Ue3: Shear
Force of 5N applied to the side of the
PCB
Moisture/Reflow
Sensitivity1
IPC/JEDEC J-STD-020D.1
MSL3
Storage (Dry
Pack)1
IPC/JEDEC J-STD-033C
MSL3
Solderability
EN/IEC 60068-2-58 Test Td
More than 90% of the electrode
should be covered by solder. Solder
temperature 245 °C ± 5 °C
1Moisture Sensitivity
Antenova ships all devices dry packed in tape on reel with desiccant and moisture level indicator sealed in an
airtight package. If on receiving the goods the moisture indicator is pink in color or a puncture of the airtight
seal packaging is observed, then follow J-STD-033 “Handling and Use of Moisture/Reflow Sensitive Surface
Mount Devices”.
Storage (Out of Bag)
The M10478 modules meet MSL Level 3 of the JEDEC specification J-STD-020D - 168 hours Floor Life (out
of bag) ≤30 °C/60% RH. If the stated floor life expires prior to reflow process then follow J-STD-033 “Handling
and Use of Moisture/Reflow Sensitive Surface Mount Devices”.
Antennas for Wireless M2M Applications
27
Product Specification 12MD-0050-2-PS