Part No. M10477
Quality and Environmental Specifications
Test
Standard
Parameters
PCB Inspection
IPC-6012B, Class 2. Qualification and
Performance Specification for Rigid Printed
Boards - Jan 2007
Assembly
Inspection
IPC-A-610-D, Class 2 “Acceptability of
electronic assemblies”
T Temperature
Range
ETSI EN 300 019-2-7 specification T 7.3
-30 °C, +25 °C, +85 °C, operating
F Damp Heat
ETSI EN 300 019-2-7 specification T 7.3
+70 °C, 80% RH, 96 hrs, non-
operating
A Thermal Shock
ETSI EN 300 019-2-7 specification T 7.3 E -40 °C ... +85 °C, 200 cycles
R Vibration
ISO16750-3
Random vibration, 10~1000Hz,
27.8m/s2, 8hrs/axis, X, Y, Z 8hrs for
each 3 axis non-operating
D Shock
ISO16750-3
Half-sinusoidal 50g, 6ms, 10time/face,
±X, ±Y and ±Z non-operating
Y Free Fall
ISO16750-3
1m height, 2 drops on opposite side
R ESD Sensitivity
JEDEC, JESD22-A114 ESD Sensitivity
+2000V - Human hand assembly
Testing Human Body Model (HBM). Class 2
JEDEC, JESD22-A115 ESD Sensitivity
A Testing Machine Model (MM), Class B
+200V - Machine automatic final
assembly
IN Shear
IEC 60068-2-21, Test Ue3: Shear
Force of 5N applied to the side of the
PCB
Moisture/Reflow
Sensitivity1
IPC/JEDEC J-STD-020D.1
MSL3
IM Storage (Dry
Pack)1
IPC/JEDEC J-STD-033C
MSL3
L Solderability
EN/IEC 60068-2-58 Test Td
More than 90% of the electrode
should be covered by solder. Solder
temperature 245 °C ± 5 °C
E 1Moisture Sensitivity
R Antenova ships all devices dry packed in trays with desiccant and moisture level indicator sealed in an airtight
package. If on receiving the goods the moisture indicator is pink in color or a puncture of the airtight seal
Ppackaging is observed, then follow J-STD-033 “Handling and Use of Moisture/Reflow Sensitive Surface Mount
Devices”.
Storage (Out of Bag)
The M10477 modules meet MSL Level 3 of the JEDEC specification J-STD-020D - 168 hours Floor Life (out
of bag) ≤30 °C/60% RH. If the stated floor life expires prior to reflow process then follow J-STD-033 “Handling
and Use of Moisture/Reflow Sensitive Surface Mount Devices”.
Antennas for Wireless M2M Applications
27
Product Specification 12MD-0049-0.6-PS