English
Language : 

UG-2828GDEDF02 Datasheet, PDF (21/29 Pages) List of Unclassifed Manufacturers – OEL Display Module
Univision Technology Inc.
6. Outgoing Quality Control Specifications
Doc. No: SAS1-XXXX-A
6.1 Environment Required
Customer’s test & measurement are required to be conducted under the following
conditions:
Temperature:
23 ± 5°C
Humidity:
55 ± 15 %RH
Fluorescent Lamp:
30W
Distance between the Panel & Lamp:
≥ 50 cm
Distance between the Panel & Eyes of the Inspector:
≥ 30 cm
Finger glove (or finger cover) must be worn by the inspector.
Inspection table or jig must be anti-electrostatic.
6.2 Sampling Plan
Level II, Normal Inspection, Single Sampling, MIL-STD-105E
6.3 Criteria & Acceptable Quality Level
Partition
Major
Minor
AQL
0.65
1.0
Definition
Defects in Pattern Check (Display On)
Defects in Cosmetic Check (Display Off)
6.3.1 Cosmetic Check (Display Off) in Non-Active Area
Check Item
Classification
Criteria
X > 6 mm (Along with Edge)
Y > 1 mm (Perpendicular to edge)
X
Panel
General Chipping
Minor
Y
X
Y
16