English
Language : 

1-1102141-2 Datasheet, PDF (21/236 Pages) List of Unclassifed Manufacturers – T E CON N E C T I V I T Y AT YOU R S E R V I C E
HTS Industrie Steckverbinder
HTS Heavy Duty Connectors
Degree of protection provided by enclosures
For safety reasons, electrical equipment needs to be protected against outside influences. The basis for the determination is the stan-
dard IEC 529 titled ‘Degree of protection provided by enclosures (IP – Code)'.
Using a standardized test procedure the extent of the protection class is verified. To classify different housings according to their protec-
tion class, a designation system is used which consists of the code – letters 'IP' and two code numbers.
Arrangement of the IP – Code (International bzw. Ingress Protection)
IP
5
6
Code Letter
1st characteristic numeral
2nd characteristic numeral
Meaning of the 1st characteristic numeral
The first numeral describes the protection of the housing against intrusion of foreign bodies as well as the protection of people against
dangerous parts or influences. Because of this, there are two descriptions and definitions for each of the first code letter.
1st
numeral
0
short description
no protection
Protection against solid obects and against access to hazardous parts
definition
1
-protection against solid foreign bodies of Ø 50mm
-protection against access to hazardous parts with
the back of a hand
A sphere of Ø 50mm, must not intrude
2
-protection against solid foreign bodies of Ø 12 mm
-protection against access to hazardous parts with
the finger
A sphere of Ø 12mm diameter, must not intrude
-protection against solid foreign bodies of 2,5 mm
3
diameter and bigger
-protection against access to hazardous parts with a
tool
A sphere of Ø 2,5mm diameter, must not intrude
4
-protection against solid foreign bodies of 1,0 mm
diameter and bigger
-protection against access to hazardous parts
with a wire
-
5
protected against dust
The probe, sphere of Ø 1,0mm, must not intrude
The infiltration of dust is not completely prevented, but it
does not infiltrate to such an extent that the operation or
the safety of the device is affected.
6
dust proof
No infiltration of dust
19 Verbindlich für Toleranzen der Abmessungen und technische Werte sind ausschließlich die neuesten TE Connectivity Kundenzeichnungen bzw. Produkt-Spezifikationen, die Sie auf Anfrage erhalten.
All specifications subject to change. Consult TE Connectivity for latest design specifications.